FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Product Description
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
2.3.2
Calculating the volumetric flow rate
The uncorrected volumetric flow rate Q
v*
is calculated from the flow velocity v
A
and the
open cross-sectional area in the meter body‘s measuring section:
This intermediate result is still dependent on Reynolds number and the properties of the
flow profile (asymmetry, swirl). It is corrected using the following formula:
Profile factor
Fixed gas pressure: mean pressure in the operating range, register #7041
"Pressure(Fixed)".
The sets of factors CC
0
to CC
4
and K
0
to K
5
are nominal size-dependent constants which
were determined by the manufacturer and which are related to a particular FLOWSIC600.
Correcting the impact of pressure and temperature on the geometry of the meter body
The geometry parameters of the meter body are based on ambient temperature of 20
°
C
and 1 bar(a) and have been optimized to minimize deviations due to the influence of
pressure and temperature. However, there is still an impact of pressure and temperature
on the geometry of the meter body and thus on the measured value. This impact is
corrected as follows:
D:
Internal diameter
of the meter body,
Reg. #7100
"InnerDiameter"
D
²
·
Qv
*
= v
A
·
4
Also
Q
v, corr
= Q
v
·
(1 + K
T
·
(T – 293.15) + K
p
·
p)
The temperature coefficient K
T
is material-specific and is 4.12 · 10
-5
K
-1
for carbon steel
and 5.23 · 10
-5
K
-1
for stainless steel.
The pressure coefficient K
p
was determined to be 6 · 10
-6
bar
-1
.
Q
v
= Q
v*
·
(1 +
f
[Q
v*
, p
abs
, CC
0...4
, PF, K
0...5
])
v
avg1
+
v
avg4
PF =
v
avg2
+
v
avg3
p
p
min
p
max
1bar
+
=
Reg. #7040
"Temperature(fixed)"
Reg. #7041
"Pressure(Fixed)"
Reg. #7118
"ExpCorrTemperature
Reg. #7117
"ExpCorrPressure"
Содержание FLOWSIC600
Страница 94: ...94 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Flow Calibration Subject to change without notice ...
Страница 120: ...120 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Installation Subject to change without notice ...
Страница 166: ...166 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Commissioning Subject to change without notice ...
Страница 186: ...186 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Maintenance Subject to change without notice ...
Страница 200: ...200 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Troubleshooting Subject to change without notice ...