206
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Appendix
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
9.1
Conformities and technical data
9.1.1
CE certificate
The FLOWSIC600 has been developed, manufactured and tested in accordance with the
following EC directives:
●
Pressure Equipment Directive 97/23/EC
●
Directive 94/9/EC (ATEX)
●
EMC Directive 2004/108/EC
●
MID Directive 2004/22/EC
Conformity with above directives has been verified and the device has been marked with
the CE label. The specific designation of the pressure equipment demanded according to
the Pressure Equipment Directive 97/23/EC under part 3.3 and 3.4 can be found in the
MDR of the FLOWSIC600.
9.1.2
Standard compatibility and type approval
The FLOWSIC600 conforms to the following norms, standards or recommendations:
●
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-11, EN 60079-26
●
OIML R 137-1, 2006, "Gas meters, Part 1: Requirements"
●
OIML D 11, 2004, "General requirements for electronic measuring instruments"
●
A.G.A Report No. 9, 2007, "Measurement of Gas by Multipath Ultrasonic Meters"
●
API 21.1 "Flow Measurement Using Electronic Metering Systems"
●
ISO 17089-1, 2010, "Measurement of fluid flow in closed conduits - ultrasonic meters
for gas - Part 1: Meters for custody transfer and allocation measurement."
●
BS 7965, 2009, "Guide to the selection, installation, operation and calibration of
diagonal path transit time ultrasonic flow meters for industrial gas applications.
2“ Type approval for commercial or custody transfer has been granted by the relevant
authorities, e.g.:
– Germany: PTB (Physikalisch-Technische Bundesanstalt), code number 7.421 /
03.05
– Netherlands: NMI (Netherlands Meetinstituut), code number B35
– Canada: Measurement Canada, Approval No. AG-0521
– Switzerland: Metrologie und Akkreditierung Switzerland, Appr. No. CH-G4-04404-00
– Europe: MID Approval, DE-08-MI002-PTB005
– GOST
9.1.3
WELMEC compliance
The interfaces and the software of the FLOWSIC600 have been designed non-reactive in
terms of the Eichordnung, Anlage 7 "Messgeräte für Gas" (calibration regulations, Annex 7
"Gas Meters") and the requirements of the WELMEC regulation 7.2, and documented
completely in document "Interface description".
The test results were archived in a traceable manner and can be provided on request.
Содержание FLOWSIC600
Страница 94: ...94 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Flow Calibration Subject to change without notice ...
Страница 120: ...120 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Installation Subject to change without notice ...
Страница 166: ...166 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Commissioning Subject to change without notice ...
Страница 186: ...186 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Maintenance Subject to change without notice ...
Страница 200: ...200 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Troubleshooting Subject to change without notice ...