58
FLOWSIC60 · Operating Instructions · 8014241/YTG9/V1-0/2016-02 · © SICK Engineering GmbH
Annex
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
7.1
Technical data
Table 2
Technical data FLOWSIC60
Meter characteristics and measuring parameters
Measured variables
Air velocity
Measurement principle
Ultrasonic transit time difference measurement
Measurement medium
Air (atmospheric conditions)
Measuring ranges
Air velocity: -10 ... 10 m/s
Measurement uncertainty
At 0.1 to 0.5 m/s: ± 0.1 m/s
At 0.5 to 10 m/s: ± 2 %
Ambient conditions
Ambient temperature
–40 °C ... +70 °C
Storage temperature
–40 °C ... +70 °C
Ambient humidity
≤
95 %
Relative humidity; non-condensing
Approvals
Ex-approvals
IECEx
Ex ia [ia] I Ma
Ex ia [ia] IIA T4 Ga
Electrical safety
CE, IECEx
Enclosure rating
IP66 / IP67
Outputs and interfaces
Signal outputs
1 analog output, passive, 4...20 mA, < 250
Ω
, galvanically isolated
1 status output, passive, galvanically isolated, acc. to NAMUR
(EN 50227)
Installation
Dimensions (W x H x D)
See dimensional drawings
Weight
Transmitter/receiver unit: approx. 4 kg
Control unit SPU: approx. 6 kg
Mounting
Universal wall/ceiling bracket,mounting components included,
sensor cable length: 15 m
Electrical connection
Voltage
13.5 to 24 V DC, intrinsically safe supply
Power consumption
≤
1 W
General
Scope of delivery
The scope of delivery depends on application and customer specifica-
tions.