FLN-EMSS1100108 — 8-pin
Figure 11: FLN-EMSS1100108 Flexi Loop node — 8-pin
The 8-pin Flexi Loop EMSS node
has one more non-safe input and one more non-safe
output
than the 5-pin Flexi Loop EMSS node. Control switches (e.g.,
pushbuttons) or
actuators (e.g.,
lamps or locks) can be connected here.
FLN-OSSD1000105 — 5-pin
Figure 12: FLN-OSSD1000105 Flexi Loop node — 5-pin
The 5-pin OSSD Flexi Loop node is suitable for connecting
safety sensors with moni‐
tored semiconductor output (OSSD)
(e.g. safety light curtains or transponder safety
switches).
In addition it has a non-safe input
. Signal outputs from the sensors (e.g. for
signaling contamination) can be connected to this input. The safety sensors connected
are tested for discrepancy and sequence errors.
FLN-OSSD1100108 — 8-pin
Figure 13: FLN-OSSD1100108 Flexi Loop node — 8-pin
The 8-pin Flexi Loop OSSD node
has one more non-safe output
than the 5-pin Flexi
Loop OSSD node. Sensor signal outputs (e.g.,
for weak signals) or LEDs (e.g.,
for reset
required) can be connected here.
PRODUCT DESCRIPTION
3
8015836/YT10/2016-05-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
21