8.2
Test notes
8.2.1
Tests before the first commissioning
The purpose of the tests before the first commissioning is to confirm the safety require-
ments specified in the national/international rules and regulations, especially in the
Machine and Work Equipment Directive.
=
Check the effectiveness of the protective device mounted to the machine, using all
selectable operating modes and functions.
=
Ensure that the operating personnel of the machine fitted with the safety controller are
instructed by the qualified safety personnel of the machine owner before beginning
work. Instructing the operating personnel is the responsibility of the machine owner.
8.2.2
Regular testing
The Flexi Classic system must be tested regularly.
In order to reach SILCL3 in accordance with EN 62
061 (see chapter 11 “Technical
specifications” on page 96), the following test must be made at least every 365 days:
•
The Flexi Classic system must be powered down.
•
The Flexi Classic system must be powered up.
•
All safety functions of the connected safety sensors must be verified.
8.2.3
Regular inspection of the protective device by qualified safety personnel
=
Check the system following the inspection intervals specified in the national rules and
regulations. This procedure ensures that any changes on the machine or manipulations
of the protective device after the first commissioning are detected.
=
Each safety application must be checked at an interval specified by you. The effective-
ness of the protective devices must be tested by qualified personnel.
=
If any modifications have been made to the machine or the protective device, or if the
safety controller has been changed or repaired, the system must be checked again as
specified in the checklist in the annex.
WARNING