3.2.4
Fitting the weatherproof cover
Weatherproof cover for analyzer
This weatherproof cover protects the sender/receiver unit (compare
comprises a base plate and a cover.
Assembly:
Push the base plate (1) sideways on the flange with tube (2), slot onto the threaded
bolts (3) of the duct-side surface of the flange plate and screw tight (
Put the cover (4) on from above.
Insert the side holding catches (5) into the counterpieces, twist and lock in.
Figure 22
Fitting the weatherproof cover for analyzer (dimensions in mm)
Weatherproof cover for external purge air unit
The weatherproof cover (
) comprises a cover and locking set.
Assembly:
Mount the locking pins from the locking set on the base plate.
Put the weatherproof cover on from above.
Insert the holding catches into the counterpieces from the side, twist and lock in.
Clearance to lift off
(492)
(365)
(239)
> 25
0
(360)
2
3
5
Duct
4
1
A
A
A -A