PRODUCT DESCRIPTION
2.2.2
Reflector/scattered light receiver
For transmission measurement, this component contains a reflector to reflect the sender
light beam back to the receiver in the sender/receiver unit and a scattered light receiver
with a light trap. Two versions are available to adapt to different internal duct diameters. A
type code identifies the versions:
Fig. 9: Reflector/scattered light receiver for short measuring paths
Reflector/scattered light receiver:
DHC-Rx
Measuring path:
- 0: Short (0.5 ... 3 m)
- 1:
Long (2.5 ... 8 m)
ß
à
Enclosure with electronics (swivel-mounted)
Mounting holes
Light trap
Opening for reflector
Handle
Attachment for scattered light receiver
Hinge
Connection for sender unit
Knurled screw
ß
Purge air connection
à
Flange