Set the switching threshold for the shape comparison for Q
2
manually
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Manual Q
2
→ Q
2
Logic
/
to → Q
2
Tolerance
→
1
00 (Note:
1
= flashing 1)
/
,
/
,
/
to the → desired
switching threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Output function Q
2
/Q
a
= switching
Mode Q
2
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
6.4.1.5
“Alarm” switching mode
6.4.1.5.1
Description
The “Alarm” switching mode is only accessible if the “Advanced” user level is activated.
Output of one (“High Active”) or no (“Low Active”) switching signal if the sensor is not
capable of generating a measured value (e. g. no object in the measuring range or
remission of the measuring object too low). Utilization of the error output is particularly
useful if the setting stipulating that the sensor retain the last valid measured value is
activated (assuming that a measurement is not possible),
ment is possible (NoMeasurement)", page 65
.
1
2
1
0
3
Figure 19: Error output (“High Active”)
1
Minimum signal level
2
Signal level starting when a measurement is no longer possible
3
Maximum signal level
1
2
1
0
3
Figure 20: Error output (“Low Active”)
1
Minimum signal level
2
Signal level starting when a measurement is no longer possible
3
Maximum signal level
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
43