TROUBLESHOOTING
10
Troubleshooting
10.1
Error message on the display
On the display are shown up to three error messages with highest priority. The mes-
sages that can appear on the display are listed in the following table.
Error
Cause
Solution
[i]OL-Qa
The ohmic load at the analog output Q
A
is too high. Reduce the load on Q
A
.
[i]SC-Qa
Short circuit at output Q
A
.
Resolve short circuit.
[i]OL-Qb
The ohmic load at the analog output Q
B
is too high. Reduce the load on Q
B
.
[i]SC-Qb
Short circuit at output Q
B
.
Resolve short circuit.
[!]InErr
System error
Contact SICK; the sensor is defective.
[i]QxOff
Supply voltage at digital input/output too low.
Increase supply voltage to achieve the desired
functionality.
[i]QaOff
Supply voltage at analog output too low.
Increase supply voltage to achieve the desired
functionality.
[i]IOLOf
Supply voltage at IO-Link interface too low.
Increase supply voltage to achieve the desired
functionality.
[i]LoFlw
Leak flow volume suppression is deactivated.
Informs you that leak flow volume suppression is
deactivated.
[i]Empty
The measurement channel is not completely full.
Check sensor installation and ensure that the
measurement channel is completely full.
[i]Simul
Simulation mode active.
Informs you that simulation mode is active.
[i]OL-Qx
Q
1
and/or Q
2
have overheated.
Reduce load on Q
1
and/or Q
2
.
[!]MFail
System error
Contact SICK; the sensor is defective.
[i]SC-Q1
Short circuit at output Q
1
.
Resolve short circuit.
[i]SC-Q2
Short circuit at output Q
2
.
Resolve short circuit.
[i]QxErr
The configured parameters for Q
1
and Q
2
have
been deleted.
Reconfigure the parameters.
[i]UVolt
The system voltage is lower than 12 V.
Increase the voltage to achieve the desired func-
tionality.
[i]OVolt
The system voltage is higher than 30 V.
Reduce the voltage to achieve the desired func-
tionality.
[i]PTmpL
Process temperature is too low (< –20 °C).
Increase process temperature.
[i]PTmpH
Process temperature is too high (> 150 °C).
Reduce process temperature.
[i]HTmpH
The electronic PCB has overheated.
Reduce the ambient temperature.
[i]HTmpL
The electronic PCB is too cold.
Increase the ambient temperature.
[!]Empty
The measurement channel is not 100% filled with
medium.
An error signal is set (3.5 mA or 21 mA is set as
QxFail).
[i]HiFrq
Pulse valency for pulse output to low or frequency
of the frequency output too high.
Increase the pulse valency or decrease the maxi
-
mum frequency.
[i]LoFrq
Frequency of the frequency output too low.
Increase the minimum frequency.
[i]Steri
Process temperature exceeds the sterilization tem
-
perature set point and stays above the sterilization
temperature reset point for at least as long as the
sterilization time.
Check the sterilization parameters.
[i]ErrFw
The firmware has been downgraded to a previous
version
Please contact SICK.
[!]Err82
System error.
Please contact SICK; the sensor is defective.
[!]Err83
System error.
Please contact SICK; the sensor is defective.
[!]Err84
System error.
Please contact SICK; the sensor is defective.