8.4
Device menu group
8.4.1
Switching the laser on and off
Switching the measurement and alignment laser on and off manually.
Parameter
Factory setting
Alignment laser on:
Switching the alignment laser on/off
Off
Measurement laser on:
Switching the measurement laser on/off
On
8.4.2
Configuring the heater
Define the switch-on temperature of the front screen heater. Heating is activated when
the ambient temperature is below the defined switch-on temperature. The hysteresis is
fixed at 2 Kelvin.
The heater can be activated via SOPAS ET, the RS-422 interface, the PROFIBUS DP
interface or the Ethernet interface. When the heater is switched on and the upper
or lower temperature warning limit is exceeded, the heater automatically switches to
automated mode.
The fogging and/or frosting of the front screen depends on the temperature, pressure
and air humidity. The dew point and/or the frost point can be calculated from these
values. To prevent the fogging and/or frosting of the front screen, the front screen
heater must be activated when the dew point or frost point is reached.
Parameter
Factory setting
-20 °C ... +20 °C
-10 °C
8.4.3
Defining the language
Selection of languages indicated on the display.
REFERENCE
8
8024560/1A19/2021-06-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
79