8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 47
Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
8.5.9
Submenu "MF1 – Dist"
This submenu is used to parameterize the multifunction output MF1 as
distance switching output.
You can get to the menu "Dist" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
MF1
→
→
Actsta
→
→
Functn
→
→
Dist
Push the
key for at least 2 seconds to get to the "Menu".
Requirements for the display
• Menu "more": Option "On"
• Menu "MFx On": Option "Enable"
• Parameter "Functn": Option "Dist"
Parameter
Description
Limit
Set distance-dependent switching threshold
Hysteresis
Set Hysteresis for the switching threshold
Table 14: Submenu "MF1 – Dist"
inactive
active
Limit
Hyst
Dist.
Fig. 24: Displaying the function "Dist."
Limit Distance-dependent switching threshold
Hyst: Switching threshold hysteresis