Calling up diagnostic data
To be able to call up information, you need an NFC-capable device, e.g. a smartphone
and the SICK Safety Assistant app provided by SICK.
b
Hold the NFC-capable mobile device near the marked NFC-area on the lower end
of the active unit to call up the diagnostic data.
Complementary information
The diagnostic data can also be read out in the voltage-free state of the protective
device. However, you will receive more information if the protective device is supplied
with voltage.
3.2.9
Status indicators
Overview
The LEDs of the active unit signal the operational status of the multiple light beam
safety device.
$
§
1 2 3 4
5 6 7 8
!
OSSD
INFO
"
Figure 6: Status indicators of the active unit
Position
LED color
Display
Labeling
!
Red/green
OSSD status
OSSD
"
Red/yellow/green
Information display;
shows the status of
the light path and
additional information
about the status dis‐
play
INFO
§
Blue/red/yellow/white Diagnostics
1, 2, 3, 4, 5, 6, 7, 8
$
Red/yellow/green
End cap with inte‐
grated LED
–
The integrated LED in the end cap of the active unit is responsible for the light behavior
of the INFO-LED.
PRODUCT DESCRIPTION
3
8024802/2020-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 LT Muting A/P
15
Subject to change without notice