Other functions
50
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
10.2
Switch delay
A time function can be activated for switching outputs Q1 and Q2. The
configured time function applies to both switching outputs. The following
functions are available:
Function
Description
Deactivated
Right after the measured distance has exceeded
the specified switching point, the state of the
switching output changes (factory setting).
Switch-on delay
The changeover of the switching output from an in-
active to an active state is time-delayed. The delay
time is adjustable. The changeover from an active
to an inactive state is not delayed.
Switch-off delay
The changeover of the switching output from an
active to an inactive state is time-delayed. The
delay time is adjustable. The changeover from an
inactive to an active state is not delayed.
ON and OFF delay
The changeover from an inactive to an active state
and vice versa is time-delayed. The delay time is
adjustable.
One-time timer
Once the switching condition has been met, the
switching output changes from an inactive to an
active state. The switching output remains in an
active state for a specified period regardless of
how long the switching condition is met. It does
not switch back to an inactive state until this time
has elapsed. Any additional changes made to the
switching condition during this period are still not
taken into account.
Table 19: Switching behavior - functions
NOTE!
An additional delay between the time at which the switch-
ing point is exceeded and the changeover of the switch-
ing output may result from the speed settings (integra-
tion time, depth of the bit filter).
SOPAS ET: “Output settings” page > “Switching delay”