Commissioning
36
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
8.5
Expert mode
Use expert mode to set the following functions:
• Function for multifunction input MF:
External teach (factory setting), laser off, multifunctional input MF deac
-
tivated
• Level for multifunction input MF:
High active (factory setting), Low active
• For DT35/DL35 distance sensors:
Output behavior for output 2:
4 … 20 mA (factory setting), 0 … 10 V, switching output Q2
Description
Active LED
LED slow … fast
Function for multi-
function input
Q1 near
• LED
slow … fast
flashes 1 x:
external teach
• LED
slow … fast
flashes 2 x:
laser off
• LED
slow … fast
flashes 3 x:
Multifunctional input MF deactivated
Level for multi-
function input
Q1 far
• LED
slow … fast
flashes 1 x:
low active
• LED
slow … fast
flashes 2 x: high
active
Output behavior
for output Q2
1)
Q2 near
• LED
slow … fast
flashes 1 x: 4 …
20 mA
• LED
slow … fast
flashes 2 x: 0 …
10 V
• LED
slow … fast
flashes 3 x: Switch
-
ing output
1) For DT35/DL35 distance sensors only
Table 8:
Overview of expert mode
Output: The output Q2 is to be set to 0 … 10 V.
1. From operating mode only: Press
select
and
set
pushbuttons simulta-
neously for longer than 10 seconds. The LED
Q1
near
lights up and the
LED
slow
…
fast
flashes cyclically according to the previous setting.
2. Keep pressing the pushbutton until the LED
Q2 near
lights up.
3. Keep pressing the
set
pushbutton until the desired option has been
set.
• LED
slow … fast
flashes 1 x: 4 … 20 mA
• LED
slow … fast
flashes 2 x: 0 … 10 V
• LED
slow … fast
flashes 3 x: switching output.
4. In order to leave expert mode, press the
select
and
set
pushbuttons
for longer than 10 seconds or wait 5 minutes without pushing the
pushbuttons.