Online Help
Chapter
2
Barcode Scanner CLV62x
CLV62x
8011967/S345/2008-04-23
©
SICK AG · Division Auto Ident · Germany · All rights reserved
21
2.2.4.1 Output control
Output control
The output of the read code contents is configured with the parameters of the
group.
Fig. 2-11:
Impact of the parameter values End of trigger (Output time) on the output time of the
code contents.
Parameter
Function
Control
Select type of control.
Output time
Select output time of the read code contents.
Delay
Enter delay between end of reading gate and output of the code
contents.
If applicable, select unit.
Output condition
Select required condition for the output of the code contents.
This condition can be configurated (see
).
Time out
Enter delay for the transmission of the reading data.
If applicable, select unit.
100 ms
Reading
gate
Output
time