2.2.4
Data processing
Tracking
The delay for the transmission of the reading data can be configured via the parameters of
the
group. This can make sense if a code is scanned just before the end of the
reading gate.
Fig. 2-10:
Impact of the Timeout parameters on the reading gate
Code summarisation
The parameters of the
group are used to configure whether several
similar codes are output as one code or as several codes.
Parameter
Function
Time out
Enter maximum time after which a read code will be output after
the end of the reading gate.
50 ms
Start
Sensor 1
Reading
gate
Parameter
Function
Separate codes based on posi-
tion
Activate/deactivate the output of similar codes as several codes.
Code distance
Enter maximum distance of codes from each other.