![SICK CLV62x Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/sick/clv62x/clv62x_online-help-manual_1264245016.webp)
Chapter
2
Online Help
Barcode Scanner CLV62x
16
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011967/S345/2008-04-23
CLV62x
EAN
Via the parameters of the
group you can set which EAN code types are to be scanned.
2.2.3.4 2/5 Interleaved
The 2/5 I
NTERLEAVED
(also called ITF) is a very common code type for the coding of numeric
information. The main fields of application are in the industrial sector. The 2/5 I
NTERLEAVED
is a binary code which encodes digits from 0-9.
Fig. 2-6:
Example of 2/5 Interleaved
General
The reading conditions for code type 2/5 I
NTERLEAVED
are configured via the parameters of
group.
Length
A length test of the barcode can be configured via the parameters of the
group.
Parameter
Function
EAN 8
Activate/deactivate scanning of code type
EAN 8
.
EAN 13
Activate/deactivate scanning of code type
EAN 13
.
Parameter
Function
Multiread #1
Enter the minimum number of required successful readings that
must be achieved to accept a barcode as valid.
Check-digit test #1
Select the type of check-digit test for the first code length.
Check-digit test #2
Select the type of check-digit test for the second code length.
Check-digit test #3
Select the type of check-digit test for the third code length.
Check-digit test #4
Select the type of check-digit test for the fourth code length.
Check-digit test #5
Select the type of check-digit test for the fifth code length.
Classification restriction
The classification restriction is displayed in %.
The classification restriction represents the scanning security.
The higher the value, the safer the scanning; but it also increases
the chance that a poorly printed code will not be scanned.
The difference between the smallest wide element and the larg-
est narrow element must be greater than the average module
width multiplied by the classification restriction.
Parameter
Function
Code length mode
Select the type of code length test.
Interval
Enter minimum length of barcode.
Enter maximum length of barcode.
Only barcodes with lengths between these two values are read.
Fixed lengths
Enter required lengths of barcode.
Only barcodes with the entered lengths are read.