Parameter set in the
main memory of the
device
6
Permanently saved
parameter set of the
device
5
Factory default setting of
the device
7
Device
2
Optional:
1
Computer with SOPAS ET
Configuration Software
3
Parameter memory module
CMC600
4
Volatile memory
à
Opened project file
with current parameter
set of the device
8
Volatile memory
à
Non-volatile memory
ß
Non-volatile memory
ß
Saved project file (*.sopas)
with archived parameter
set of the device
9
Data base on e. g. hard drive
(non-volatile memory)
á
Permanently saved
parameter set of the
device
5
Non-volatile memory
ß
Figure 27: Configuration with SOPAS ET and saving the parameter set
1
Optional
2
Device
3
Computer with SOPAS ET configuration software
4
CMC600 parameter cloning module
5
Permanently saved device parameter set
6
Parameter set in the working memory of the device
7
Factory-set defaults for the device
8
Opened project file with current device parameter set
9
Saved project file with archived device parameter set
ß
Nonvolatile memory
à
Volatile memory
á
Database on, for example, a hard drive (non-volatile memory)
Saving behavior using the “Permanent” saving option:
The device is connected to a CDB or CDM connection module. The connection module
contains a CMC600 parameter cloning module: When the currently valid parameter set
is saved in the device, this is also done externally in the CMC600.
Defective device: Support for replacement with no manual reconfiguration required:
NOTE
The device replacement will only be successful if the defective device is replaced by an
exchange unit of the
same type
. The defective device must have been operated with
automated parameter cloning before the failure.
To replace a defective device with an exchange unit, a CMC600 with the current param‐
eter set must be present in the connection module connected to the defective device.
For more information,
see "Device exchange with transmission of the current configura‐
7.4
Adjusting the device for operational use
Before the final adjustment of the device, complete the electrical installation. Put the
device into operation.
1.
Loosen the bracket screws so that the device can be aligned.
2.
Align the device so that the angle between the scanning line and the bar code
stripes is almost 90°.
COMMISSIONING
7
8017840/19OF/2021-10-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x
49