Quick Finder
Installation steps (overview)
Reading trigger via “Sensor 1“ switching input (default setting)
1.
Check whether the delivery is complete.
2.
Install the CLV in the reading station and align to the object with bar code.
3.
Install the AMV/S 40 connection module and cover the terminal designations in the
connection area.
4.
Connect the CLV to the AMV/S 40 connection module.
5.
Install the reading-pulse sensor.
6.
Connect the reading-pulse sensor to the "Sensor 1" switching input in the AMV/S 40.
7.
Install the sensor for the distance detection.
8.
Connect the distance sensor to the "Sensor 2" switching input in the AMV/S 40.
9.
Connect the host to the "Host interface" in the AMV/S 40.
Adapt the AMV/S 40 to the host interface type of the CLV.
10. Switch on the supply voltage of the AMV/S 40.
After the CLV has been started the "Device Ready" LED lights up. The beeper signals
that Reading mode has been started by means of two consecutive sounds.
Line scanner with oscillating mirror:
In reading mode the CLV deflects the scan line in the default setting with a frequency of
1 Hz around the position CW = 50 at a maximum angle of
±
20
°
.
11. Switch on the PC and start Windows
TM
(minimum requirement Windows 95
TM
).
12. Install the supplied "CLV-Setup" user software, "CLV-Setup Help" online help and, if re-
quired, "I-ViewPro
TM
" HTML browser from the CD-ROM on the PC.
13. Connect the PC to the terminal interface of the CLV.
To this purpose connect the PC via the RS-232 data connection cable to the "Service"
plug in the AMV/S 40.
14. Start the "CLV-Setup" software.
CLV-Setup starts the communication with the CLV and copies the parameter record of
the CLV by means of an upload. The parameter record is displayed in the tab cards.
15. Carry out a test read run with a test bar code specimen (pulse the CLV correspondingly).
Display the read result in the terminal emulator of CLV-Setup.
16. Configure the CLV for the application by means of the setting options on the tab cards
in CLV-Setup.
Copy the modified parameter record temporarily to the CLV per download.
Do not
switch off the supply voltage of the AMV/S 40 (of the CLV).
17. Test the application under real conditions.
18. Check the correct data transfer of the CLV to the host.
19. If necessary, correct and optimize the set parameter values.
Copy the parameter record
permanently
to the CLV per download.
20. Save the parameter record as a configuration file "*.scl" in CLV-Setup!
The CLV is ready to operate with the
application-specific