O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
1 1 0
APPENDIX
13.1.14
Error codes (sFA)
Error code
Description
Example
sFA
1
Method requires higher user level
sWN command without prior
log on
sFA
3
Unknown variable
sWN
parFxdSpd
+10
sFA
4
Variable value range violated
sWN
parTeachCycles
+10
sFA
A
Variable is write-protected
sWN
mvVolumeSum
+1000
sFA
B
Invalid command for this method
sWT
parFixedSpeed
+10
sFA
F
Value range for the variable type
violated
sWN
parTeachCycles
-1
sFA
11
Unknown character in the telegram
sWN
parFixedSpeed
+1y0
(Other)
Please contact SICK support.