O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZNC5/2017-06-06 |
S I C K
Subject to change without notice
9 0
APPENDIX
13.1.13
Service data
Permissible commands:
sRN, sEN
Variable name
Description
Variable type Value range
Unit
ODpwrc
Operating data: Power up
counter
uint_32
OPcurtmpdev
Device status: Current tem-
perature
float_32
°C
SCdevicestate
Device status: Operational
status
uint_8
0: Busy
1: Ready
2: Error
LCMstate
Device status: Contamina-
tion
uint_8
0: No contami-
nation
1: Warning
2: Contaminat-
ed
3: Fail
ODoprh
Operating data: Operating
hours
uint_32
0 ... 4 x 10
9
1/10 h
ODopdaily
Operating data: Daily oper-
ating hours
float_32
0 … 4 x 10
8
1 h
DIuser
Service information: Last
user
string
(max. 18
characters)
DIpara
Service information: Last
configuration
string
DD.MM.YYYY
Date
DIparatm
HH:MM
Time
Permissible commands:
sRN, sWN
Variable name
Description
Variable type Value range
Unit
DIlstmt
Service information: Last
maintenance
string
DD.MM.YYYY
Date
DInxtmt
Service information: Next
maintenance
string
DD.MM.YYYY
Date
13.1.14
Error codes (sFA)
Error code
Description
Example
sFA
1
Method requires higher user level
sWN command without prior
log on
sFA
3
Unknown variable
sWN
parFxdSpd
+10
sFA
4
Variable value range violated
sWN
parTeachCycles
+10
sFA
A
Variable is write-protected
sWN
mvVolumeSum
+1000
sFA
B
Invalid command for this method
sWT
parFixedSpeed
+10
sFA
F
Value range for the variable type
violated
sWN
parTeachCycles
-1
sFA
11
Unknown character in the telegram
sWN
parFixedSpeed
+1y0
(Other)
Please contact SICK support.