O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZNC5/2017-06-06 |
S I C K
Subject to change without notice
6 6
FAULT DIAGNOSIS
Display
Possible cause
Possible measures
Too many invalid measuring
points within a scan
Check the ambient conditions (dust, reflec
-
tive surfaces, contamination on the front
screen, bulk properties).
Adjust the tolerance against reflection to the
application (see "8.3.2 Tolerance against
If necessary, activate optimization for out-
door applications (see "8.3.3 Optimization for
outdoor applications“ on page 58).
Tab. 16: Error and status indicators on the 7¬segment display
10.4
Status indication BAM100
Fig. 39: status indication
LEDs diagnosis of voltage supply
LED (Power LEDs)
Meaning
Power LED Us off
Bus Coupler has no voltage 24 V
DC
Power LED Up off
No 24 V
DC
power supply connected to the power contacts
LEDs diagnosis of K-Bus
LED (K-Bus)
Meaning
K-Bus RUN
on or flashing - K-bus running
K-Bus ERR
flashing (see error code)
LEDs diagnosis of ethernet
LED (Ethernet)
Meaning
LINK/ACT
on - LINK available, flashing - LINK available and communica
-
tion
ERROR
flashing - DHCP or BootP active. Waiting for an IP address
COM
Communication with controller available