4
MOUNTING
36
8022161-1B29 / V2-0/2021-04|SICK
T R A N S L A T I O N O F A N O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | Backup Assistance System
Subject to change without notice
4.4.4
Fastening signal light bar with metal strip
The scope of delivery includes a self-securing strap with metal strip holder.
▸
Position the metal strip holder behind the device.
▸
Screw on the metal strip holder clockwise using the 4x M5 screws included with
delivery. Use a 3 mm Allen key for this purpose.
NOTE
The recommended applied tightening torque is 3.5 Nm.
Fig. 34: Screwing down metal strip holder
Position rubber pad to protect the metal strip holder.
Feed the self-securing strap through the metal strip holder and secure it with sufficient
force (minimum 100 N, maximum 450 N).
Fig. 35: Passing the self-securing strap through the metal strip holder and securing it
▸
NOTE
If necessary, shorten the length of the self-securing strap (2 x 520 mm) by
cutting off the protruding end.