Figure 22: Example for the parameterization of subindex 1A00.01h
60040020h
•
Object = 6004h
•
Subindex = 00h
•
Data length = 20h (32 Bit)
NOTE
In the factory the encoder’s Transmit PDOs are set to devicespecific triggering. As a
consequence the encoder outputs all Transmit PDOs once on start-up. However the
event timer is at 0. For this reason the Transmit PDOs are initially only output once.
For the cyclic or acyclic output of the Transmit PDOs by the encoder, there are the
following options:
b
Change the event timer in the objects 1800h … 1803h
b
Configure a trigger event using the CoS event handling configuration
b
Change the transmission type in the objects 1800h … 1803h
.
5.8.5
Speed measurement
The speed measurement is configured using the object
2002h – Speed Calculation
Configuration
.
Figure 23: Example for the parameterization of object 2002h
Using the subindex
2002.02h – Format: Measuring Units
you can define the units in
which the speed is transmitted.
INTEGRATION IN CANOPEN
5
8016869/1EF3/2021-12-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 CANopen
AHS/AHM36 CANopen Inox
39
Subject to change without notice