a
1
2
3
3
S
et
Es
c
<
<
Figure 12: Arranging a distance sensor with the data transmission system
1
Distance sensor
2
Reflector
3
ISD300, ISD400-1xxx or ISD400-6xxx
a
Minimum distance, a ≥ 100 mm
5.6
Mounting the alignment bracket and distance sensor
The distance sensor is installed using the optional alignment bracket
The alignment bracket is suitable for mounting on horizontal and vertical surfaces.
If the device is used for vertical measurements (e.g.in the stroke axis of an automated
storage and retrieval system), you can mount the alignment bracket horizontally or use
the optional deflector mirror.
NOTE
The operation must be accessible.
1.
Mount the alignment bracket using the four slotted holes with the supplied screws.
MOUNTING
5
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
25
Subject to change without notice