6
Commissioning
6.1
Parameterization
The WI180C-EN can be integrated in Ethernet/IP control systems in different ways.
NOTE
All configuration information relates to controls manufactured by Beckhoff, which are
configured and diagnosed with the TwinCAT™ configuration tool.
Integration in Ethernet/IP
The WI180C-EN can be integrated in Ethernet/IP in the following ways:
•
As a generic module:
All module settings must be selected manually.
•
Using an EDS file:
The WI180C-EN module settings have been predefined.
Configuration
The parameters are configured offline, then written to the WI180C-EN and activated on
switching to online mode. The following options are available for configuring the
WI180C-EN:
•
The configuration assembly
•
The controller tags in the controller organizer
Configuration options when integrating as a generic module
•
If you have integrated the WI180C-EN as a generic module, then you can configure
it dependent on the Connection Parameters entered.
•
If the
configuration assembly
is activated under
Connection Parameters
, you must per‐
form the configuration using the configuration assembly.
Configuration options when integrating using the EDS file
•
If you have integrated the WI180C-EN using the EDS file, then you can configure it
dependent on the selected instances of the I/O assemblies.
Table 4: Overview of connection types
Connection type
Assembly
Description
Note
Exclusive owner with
config
I/O assembly: 101
through 103
Configuration assem‐
bly: 100
This connection type sends and receives
process data and contains a configuration
assembly
Input only without con‐
fig
I/O assembly: 104
Configuration assem‐
bly: –
This connection type sends process data and
does not contain a configuration assembly.
6.2
Integration as a generic module
1.
Right-click on the Ethernet icon and select the
New Module…
command.
✓
The
Select Module
dialog box opens.
2.
In the
Select Module
dialog box, select the
By Category
index card.
3.
Open the
Communication
structure tree.
4.
In the
Communication
structure tree, select the
ETHERNET-MODULE (Generic Ethernet
Module)
module and click on
OK
.
✓
The
Module Properties [module name]
dialog box opens.
COMMISSIONING
6
8024950/2019-11-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | WI180C-EN
13