PRO2-Navigator Setup Software
64
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
6.4.7
Output Settings
This section explains the details of the output setup screen.
Reference: For details on the output settings, see “7.8 Output Settings.”
1
2
5
7
4
3
6
Number Display item Description
Operation
1
Output
values
Displays the measured results of
outputs 1, 2, and 3.
Displays the measured results of the target outputs.
Click an output to display its detailed settings
3
.
The currently selected output is displayed in light blue.
2
Analog Out
Displays the current value of
analog output.
Displays the measured result of the analog current output .
Displays the analog output current and measured value.
3
OFFSET
Executes the offset on/clear from
the specified output (output 1, 2, or
3).
Execute the offset to set the current measured value to
the value set with “Offset.”
(Example: If “Offset” is set to “0.000,” the current value
will become “0.”)
4
Detailed out-
put settings
Displays the detailed output settings
of the target.
Displays the detailed settings of the output selected with
1
.
You can change settings by selecting and typing values.
5
Detailed
analog out-
put settings
Configure the detailed analog output
settings.
Displays the setting values in the input boxes.
6
Current
Display
Enters the current measured value
into the specified item.
Click to enter the current measured value in the target item.
7
Send PARAM Click to finish setting the
measurement.
Click to write the setting details to the Profiler 2.
(The same operation is performed as when you click
“Send Param” in the upper left of the screen.)