8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
27
Operating the Sensor
Setting
item
Bank Setting value/
default value
General description
Inner hold
—
Each time that the SET button is pressed, the hold function will be turned on or off.
The condition to enable this function is: IN2: BANK2.
OFF
ON
Inner trig
—
Each time that the SET button is pressed, the trigger will be turned on or off.
The condition to enable this function is: IN3: BANK3.
N.O.
The trigger turns on when input is applied.
N.C.
The trigger turns off when input is applied.
Input polar N
Set the operation polarity of the external input terminals.
N.O.
The trigger turns on when input is applied.
N.C.
The trigger turns off when input is applied.
Trig action
Y
Set the measurement operation to perform when trigger input is received.
Cont
Measurements will be performed continuously.
1shot
One measurement will be performed when trigger input is received.
Count
When the predetermined number of trigger inputs are received,
one measurement will be performed see Trig count.
Trig count
Y
Set the count to use when “Trig action” is set to “Count.” The condition to enable this function is:
Trig action: Count.
1 to 4095
[
1
]
[Unit: Number of times]
Inp filter
N
Set the external input filter time to prevent chattering.
5 to 1275
[
5
]
[Unit: μs] * You can set this value
in steps of 5 μs.
Trig delay
Y
Set the delay time between the trigger meeting the camera conditions and the camera actually taking
images.
5 to 20475
[
5
]
[Unit: μs] * You can set this value in steps of 5 μs.
Offset
target
N
Select the target on which to execute the offset.
The condition to enable this function is: IN4: Offset.
Indivi
Depending on the input time, the offset will be executed on or cleared from
OUT1, OUT2, or OUT3 or on all of these.
All
The offset will be executed on or cleared from all of OUT1, OUT2, and OUT3.
OUT1
The offset will be executed on or cleared from OUT1.
OUT2
The offset will be executed on or cleared from OUT2.
OUT3
The offset will be executed on or cleared from OUT3.
5.2.3
Storage
Configure the settings related to the storage function.
Serial communication or PRO2-navigator is required to check stored data.