background image

2

Safety information

2.1

Intended use

The TiM8xx DistanceGuard is a combination of a 2D LiDAR sensor (

TiM8xx

) and a Sen‐

sorApp (

DistanceGuard

) developed for a distance monitoring application.

The 2D LiDAR sensor scans its environment in a plane without making contact, merges
distance clusters into anonymous objects using the app and determines their distance
to one another.

If the distance between two people undercuts an adjustable threshold value, the device
sends a signal.

The number of identified objects can also be output, and a maximum number can be
set for this purpose as well. Distancing rules, for example when standing in line, are
therefore easy to follow. Adjustments can be made easily and on short notice if the
rules change.

SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.

2.2

Improper use

Any use outside of the stated areas, in particular use outside of the technical specifica‐
tions and the requirements for intended use, will be deemed to be incorrect use.

The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.

The device must not be used in explosion-hazardous areas, in corrosive environ‐
ments or under extreme environmental conditions.

Any use of accessories not specifically approved by SICK AG is at your own risk.

WARNING
Danger due to improper use!

Any improper use can result in dangerous situations.
Therefore, observe the following information:

Product should be used only in accordance with its intended use.

All information in these operating instructions must be strictly observed.

Shut down the product immediately in case of damage.

2.3

Internet protocol (IP) technology

NOTE

SICK uses standard IP technology in its products. The emphasis is placed on availability
of products and services.
SICK always assumes the following prerequisites:

The customer ensures the integrity and confidentiality of the data and rights
affected by its own use of the aforementioned products.

In all cases, the customer implements the appropriate security measures, such

 

as

network separation, firewalls, virus protection, and patch management.

SAFETY INFORMATION

6

O P E R A T I N G   I N S T R U C T I O N S | TiM8xx DistanceGuard

8025963//2020-08-05 | SICK

Subject to change without notice

Содержание 1112243

Страница 1: ...O P E R A T I N G I N S T R U C T I O N S TiM8xx DistanceGuard 2D LiDAR sensors...

Страница 2: ...only permissible within the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission of SI...

Страница 3: ...ication 13 3 6 Principle of operation 13 3 6 1 Measurement principle 13 3 6 2 Distance monitoring application 13 4 Transport and storage 15 4 1 Transport 15 4 2 Unpacking 15 4 3 Transport inspection 1...

Страница 4: ...lan 32 8 2 Cleaning 32 9 Troubleshooting 33 9 1 General faults warnings and errors 33 9 2 Repairs 33 9 3 Returns 33 9 4 Disposal 34 10 Technical data 35 10 1 Features 35 10 2 Performance 35 10 3 Inter...

Страница 5: ...operating the machine or system in which the device is integrated For information about this refer to the operat ing instructions of the specific machine 1 2 Explanation of symbols Warnings and impor...

Страница 6: ...ntended use will be deemed to be incorrect use The device does not constitute a safety component in accordance with the respec tive applicable safety standards for machines The device must not be used...

Страница 7: ...ir Technical modifications Use of unauthorized spare parts consumables and accessories With special variants where optional extras have been ordered or owing to the latest technical changes the actual...

Страница 8: ...in their particular application Commissioning configura tion Basic knowledge of the computer operating system used Basic knowledge of the design and setup of the described con nections and interfaces...

Страница 9: ...ust be complied with WARNING Risk of injury and damage caused by potential equalization currents Improper grounding can lead to dangerous equipotential bonding currents which may in turn lead to dange...

Страница 10: ...pe ordered 2 fastening clips 2 M3 x 5 mm screws TiMxx1 only TX6 screwdriver for the plastic cover of the micro USB female connector Without connecting cables 1 Printed safety notes multilin gual Quick...

Страница 11: ...cluded in scope of delivery 2 M3 threaded mounting hole 2 8 mm deep blind hole thread max tightening torque 0 8 Nm 3 Optics cover 4 Receiving range light inlet 5 Transmission range light emission 6 Pu...

Страница 12: ...ng 3 4 Type code The devices of the product family are arranged according to the following type code TIM x y z aa bb c dd 1 2 3 4 5 6 7 8 9 Table 3 Type code Position Description Characteristic 1 Devi...

Страница 13: ...is marked by a circular indentation in the center of the optics cover If a laser beam strikes an object the position of that object is deter mined in terms of distance and direction Figure 3 The 2D L...

Страница 14: ...3 270 2 Distance infringement 6 Min distance indication 5 ROI 4 7 1 1 Sensor blind spot 2 Scanning area 3 Taught in background 4 Defined region of interest ROI 5 Blue circle Defined minimum distance a...

Страница 15: ...mpleteness and for any damage that may have occurred in transit In the case of transit damage that is visible externally proceed as follows Do not accept the delivery or only do so conditionally Note...

Страница 16: ...periods of longer than 3 months check the general condition of all components and packaging on a regular basis 4 TRANSPORT AND STORAGE 16 O P E R A T I N G I N S T R U C T I O N S TiM8xx DistanceGuard...

Страница 17: ...eflective surfaces in the scanning range e g stainless steel aluminum glass reflectors or surfaces with these types of coatings Protect the device from moisture contamination and damage Make sure that...

Страница 18: ...tored The marking 90 axis on the upper side of the optics cover serves as a alignment aid View live measurement data on the PC for exact align ment see Operation page 27 and use alignment aid or scan...

Страница 19: ...Figure 5 Distance 200 mm MOUNTING 5 8025963 2020 08 05 SICK O P E R A T I N G I N S T R U C T I O N S TiM8xx DistanceGuard 19 Subject to change without notice...

Страница 20: ...is connected to the peripheral devices voltage supply any local trigger sen sor s system controller via shielded cables The cable shield for the data cable for example rests against the metal housing...

Страница 21: ...ues can no longer be complied with and that the safe operation of the device data interfaces can no longer be guaranteed Measures for widely distributed system installations On widely distributed syst...

Страница 22: ...ler 2 Device 3 Voltage supply 4 Grounding point 3 5 Insulated mounting 6 Grounding point 2 7 Ground potential difference 8 Grounding point 1 9 Metal housing Shielded electrical cable Even in the event...

Страница 23: ...wed plug con nectors or protective caps Protect the device from dust and moisture when the plastic USB cover is open All circuits connected to the device must be configured as SELV or PELV circuits SE...

Страница 24: ...ing output 3 Device over loaded Black 8 OUT 4 Switching output 4 Reserved Gray 9 INGND Common ground for all inputs Reserved White 10 IN 3 Switching input 3 Reserved Violet 11 IN 4 Switching input 4 R...

Страница 25: ...puts are shown below Device 1 OUT X 2 X Y GND Vout 3 4 Figure 10 Wiring of digital output PNP version 1 Device 2 Signal OUT X 3 Output voltage Vout 4 If an inductive load is present Provide an arc sup...

Страница 26: ...lting fall in voltage This is calculated as follows U 2 x length x current conductance value x cross section Conductance value for copper 56 m mm2 6 ELECTRICAL INSTALLATION 26 O P E R A T I N G I N S...

Страница 27: ...ayed 7 2 Overview 1 2 3 4 5 1 Show Hide menu bar buttons and open start menu display of open menu 2 Device information display 3 Menu bar 4 User level button and display 5 Workspace 7 3 User levels Th...

Страница 28: ...a blue circle whose diameter corresponds to the minimum distance to be observed If two circles intersect the minimum distance has been undercut Live information The live information shows the current...

Страница 29: ...maximum number of people is under cut the respective status display changes from green to red and switch ing output OUT2 activates Teach Background Teach in the background again It is saved automatic...

Страница 30: ...ween clusters of one person mm Maximum distance of clusters of the same person Depends on the installation height of the sensor arms and legs continue to be correctly assigned factory setting 0 7 m Te...

Страница 31: ...ted minimum distance in mm http 192 168 0 1 api crown BasicDistanceGuard setMinDistanceThreshold Use distance value as JSON Payload or Body raw Example for 1 m args value 1000 The changed value is not...

Страница 32: ...s on the place of use ambi ent conditions or operating require ments Recommended At least every 6 months Specialist Check that all unused connections are sealed with protective caps Depends on ambient...

Страница 33: ...es are impre cise Optics cover contaminated Clean the cover Highly glossy objects in the field of view of the sensor Modify Remove objects or change angle of inclination and teach in the background ag...

Страница 34: ...y specific waste disposal regulations Do not dis pose of the product along with household waste NOTICE Danger to the environment due to improper disposal of the device Disposing of devices improperly...

Страница 35: ...e typ 67 ms Detectable object shape Almost any Systematic error 60 mm 1 Statistical error 20 mm 1 Integrated application DistanceGuard Maximum number of peo ple in the region of interest 20 Maximum su...

Страница 36: ...rface plastic cover Protection class III IEC 61140 2016 1 Weight 250 g without connecting cables Dimensions L x W x H 60 mm x 60 mm x 86 mm 10 5 Ambient data Variant TiM8xx DistanceGuard Object remiss...

Страница 37: ...housing EN 61010 1 2011 07 Damp heat 25 55 C air humidity 6 cycles EN 60068 2 30 2005 Temperature change 25 50 C 10 cycles EN 60068 2 14 2009 TECHNICAL DATA 10 8025963 2020 08 05 SICK O P E R A T I N...