Approach
Clean the front screen:
1.
Make sure that the dangerous state of the machine is and remains switched off
during the cleaning.
2.
Remove dust from the front screen using a soft, clean brush.
3.
Moisten a clean, soft towel with anti-static plastic cleaner and use it to wipe the
front screen.
4.
Check the effectiveness of the protective device.
Further topics
•
10.3
Replacing the device
Important information
DANGER
Hazard due to lack of effectiveness of the protective device
If an unsuitable configuration has been saved, it may cause the dangerous state to not
end in time.
b
Make sure that the configuration is restored after replacing the device.
b
Make sure that the safe multibeam scanner is aligned correctly after replacing the
device.
Approach
1.
Disconnect the connecting cables to the safe multibeam scanner.
2.
Unscrew the fixing screws and remove the defective safe multibeam scanner.
3.
Mount the new safe multibeam scanner.
4.
Reconnect the connecting cables to the new safe multibeam scanner.
5.
Configure the safe multibeam scanner.
NOTE
You can use the Safety Assistant app to copy the verified configuration of a device
and transfer it to a new device.
6.
Perform commissioning again, taking particular care to conduct all of the thorough
checks described.
Further topics
•
"Mounting the device", page 59
•
•
"Reading and transferring the configuration using the Safety Assistant app",
page 70
•
10.4
Regular thorough check
The test is intended to ensure that the hazardous area is monitored by the protective
device and any attempted access to the hazardous area is prevented.
b
Carry out the checks according to the instructions from the manufacturer of the
machine and from the operating entity.
MAINTENANCE
10
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
91
Subject to change without notice