4
Mounting
4.1
Scope of delivery
•
Array sensor in the version ordered
•
Quickstart
4.2
Installation requirements
•
For the typical space requirements for the device, see the type-specific dimen‐
sional drawing,
•
Comply with technical data, such as the permitted ambient conditions for opera‐
tion of the device (e.g., temperature range, EMC interference emissions, ground
potential).
•
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
•
Protect the device from direct sunlight.
•
The device must only be mounted using the pairs of fixing holes provided for this
purpose.
•
Shock and vibration-free mounting.
4.3
Mounting the device
1.
Install the sensor via the fixing hole so that the light spot is positioned (longitudi‐
nally or transversely depending on the operating mode) on the object to be
detected.
Observe the sensing range variation and tolerances.
2.
In the case of high-gloss materials, angle the AS30 Core Edge at >-8° at the side
for better detection reliability.
-8°/ 0°
-8°/ 0°
l
X
Sensing distance/Reading field
25 mm / 30 mm
100 mm / 45 mm
1095581
1095582
4
MOUNTING
12
O P E R A T I N G I N S T R U C T I O N S | AS30 Core
8022080.15LJ/2020-05-07 | SICK
Subject to change without notice