PGT
PGT-08-S@SOPAS
You can define the following parameters during programming:
Parameter
DF
S60B-
xxPxxxxxx
DF
S60B-
xxMxxxxxx
DF
S60A
-xxPxxxxxx
DF
S60A
-xxMxxxxxx
DFV60A
-22Pxxxxxx
DF
S2xA
-xxPxxxxxxxx
VF
S60A
-xxPxxxxxx
Description
Resolution
B: 1 to
10000
A: 1 to
65536
1 to 65536
1 to 65536
1 to 65536
Defines the number of pulses per revo
-
lution.
Counting direction
(CW/CCW)
X
X
X
X
Enables the signal sequence to be
changed between A before B and B
before A.
Zero pulse Width
electrical/me-
chanical
X
X
X
X
Defines the duration of the zero pulse in
relation to a signal period (electrical) or
a revolution (mechanical) of the encoder
(type-dependent).
Electrical interface
TTL/HTL
X
X
X
X
Defines the output interface for the incre
-
mental signals.
Zero set
X
X
X
X
Assigns the value 0 to the current shaft
position.
Reset to factory
settings
X
X
X
X
Resets all parameters to the factory
settings of the encoder.
b
After programming, print (
) a label with the programmed data and
stick it onto the encoder.
This means that the settings with which the encoder is being used are visible from
the outside.
Standard labels are suitable for printing.
Note:
Data entered is written to the encoder immediately and directly as long as this has not
been altered in the SOPAS configuration (see online help).