9. Warranty and Liability  

(Effective January 2018) 

Siargo  warrants  the  products  sold  hereunder,  properly  used,  and  properly  installed  under normal 
circumstances and service. As described in this user manual, it shall be free from faulty materials or 
workmanship for 180 days for OEM products and 365 days for non-OEM products from the date of 
shipment.  This  warranty  period  is  inclusive  of  any  statutory  warranty.  Any  repair  or  replacement 
serviced product shall bear the same terms in this warranty.  

Siargo makes no warranty, representation, or guarantee and shall not assume any liability regarding 
the suitability of the products described in this manual for any purposes that are not specified in this 
manual. The users shall be held for full responsibility for validating the performance and suitability 
of the products for their particular design and applications. For any of the misusage of the products 
out  of  the  scope  described  herein,  the  user  shall  indemnify  and  hold  Siargo  and  its  officers, 
employees, subsidiaries, affiliates, and sales channels harmless against all claims, costs, damages, 
and expense or reasonable attorney fee from direct or indirect sources.     

Siargo  makes  no  other  warranty,  express  or  implied,  and  assumes  no  liability  for  any  special  or 
incidental damage or charges, including but not limited to any damages or charges due to installation, 
dismantling, reinstallation, etc. other consequential or indirect damages of any kind. To the extent 
permitted by law, the exclusive remedy of the user or purchaser, and the limit of Siargo's liability for 
any and all losses, injuries, or damages concerning the products, including claims based on contract, 
negligence,  tort,  strict  liability,  or  otherwise  shall  be  the  return  of  products  to  Siargo,  and  upon 
verification of Siargo to prove to be defective, at its sole option, to refund, repair or replacement of 
the products. Regardless of form, no action may be brought against Siargo more than 365 days after 
a cause of action has accrued. The products returned under warranty to Siargo shall be at the user or 
purchaser's risk of loss and will be returned, if at all, at Siargo's risk of loss. Purchasers or users are 
deemed to have accepted this limitation of warranty and liability, which contains the complete and 
exclusive limited warranty of Siargo. It shall not be amended, modified, or its terms waived except 
by Siargo's sole action.  

This manual's product information is believed to be accurate and reliable at the time of release or 
made  available  to  the  users.  However,  Siargo  shall  assume  no  responsibility  for  any  inaccuracies 
and/or  errors  and  reserves  the  right  to  make  changes  without  further  notice  for  the  relevant 
information herein. 

This warranty is subject to the following exclusions: 

(1)

 

Products  that  have  been  altered,  modified,  or  have    been  subject  to  unusual  physical  or  
electrical  circumstances  indicated  but  not  limited  to  those  stated  in this  document  or  any 
other actions which cannot be deemed as proper use of the products; 

Содержание AM1000 Series

Страница 1: ...AM1000 User Manual Insertion MEMS flow temperature and humidity sensors 2021 Siargo Ltd VB 0 1...

Страница 2: ...3100 De La Cruz Boulevard Suite 210 Santa Clara California 95054 USA Tel 1 408 969 0368 Email info siargo com Copyright 2021 and Liability Disclaimer Siargo Ltd and its subsidiaries reserve the right...

Страница 3: ...s product according to the specified parameters Only the trained or qualified personnel shall be allowed to perform product services Be cautious for electrical safety and even it operates at a low vol...

Страница 4: ...rface read write sequences 13 5 2 RS485 Modbus communication protocol 14 5 2 1 Communication parameters 14 5 2 2 Frame 14 5 2 3 Function codes 15 5 2 4 Registers 15 6 Product selection and order infor...

Страница 5: ...5 www Siargo com AM1000 User Manual 10 Service contact and information 23 Appendix I Sensor evaluation kit 24 Appendix II Document history 25...

Страница 6: ...ctured with the company s proprietary MEMS micro electro mechanical systems sensing technology and package technology that offers programmable flow speed data with a dynamic range of 100 1 as well as...

Страница 7: ...ordered together Please check immediately for the integrity of the product and the accessories if any abnormality is identified please notify the distributor sales representative or manufacturer as so...

Страница 8: ...s defined in Table 3 2 For the detailed protocols of the corresponding option please refer to Section 5 WIRE COLOR DEFINITION Red VCC power supply 8 24Vdc Black GND ground Yellow SCL I2C clock RS485 A...

Страница 9: ...he probe to properly install the probe per the application requirements For the open space measurement applications no requirements for the probe positioning but the flow data are only relevant to whe...

Страница 10: ...ns the upstream of the meter should have a 20xDN straight pipe length and downstream should have a 5xDN straight pipe length Figure 4 2 Installation with correct upstream and downstream space Figure 4...

Страница 11: ...harp turns and other cases as described in OIML R137 as those would generate flow instability and causing unstable outputs c The flow direction should be aligned as close as possible with the arrow on...

Страница 12: ...es 05H 1 I2 C address Write Bit 0 is R W flag bit Bit 1 Bit 7 are available 82H 12 Serial number Read ASCII 83H 4 Flow speed Read Int32 1000 in m sec 85H 1 I2 C address Read Bit 7 Bit 1 BEH 1 Temperat...

Страница 13: ...13 www Siargo com AM1000 User Manual 5 1 3 I2C interface read write sequences...

Страница 14: ...e 5 2 1 Communication parameters The PC UART communication parameters are listed in table 5 2 1 Table 5 2 1 PC UART communication parameters Parameters Protocol RTU Baud rate Bits per second 38400 bps...

Страница 15: ...ub class of the standard Modbus function codes These codes are used to set or read the registers of the product Table 5 2 3 function codes Code Name Functions 0x03 Read register Read register s 0x06 S...

Страница 16: ...he broadcast address the default value is 1 Flow speed 0x0002 0x00o3 Write N Read Y Description Current flow speed Value type UINT 32 Notes Flow speed Value 0x0002 65536 value ox0003 1000 e g for a fl...

Страница 17: ...aced either through the Siargo website www siargo com or the sales office For large quantities please contact the sales office distributors or sales representatives Siargo is making every effort to en...

Страница 18: ...ow speed response time 10 msec Working temperature 10 65 C Temperature coefficient 0 12 C Temperature accuracy 0 5 C Temperature resolution 0 04 C Humidity accuracy 2 0 20 80 RH otherwise 5 0 max RH H...

Страница 19: ...arameter alternations Please refer to the company s US patents and other publications made available to the public for additional information The temperature sensor is made on a silicon substrate and...

Страница 20: ...he sensor does not have a strong flow restrictor or conditioners to handle the flow instability that may exist in the system Therefore to compare the metrology data the user should ensure the system i...

Страница 21: ...ation etc other consequential or indirect damages of any kind To the extent permitted by law the exclusive remedy of the user or purchaser and the limit of Siargo s liability for any and all losses in...

Страница 22: ...smantled for whatever reasons 4 Products that have been subject to working conditions beyond the technical specification as described by this manual or related datasheet published by the manufacturer...

Страница 23: ...Clara California 95054 USA Phone 01 408 969 0368 Email info Siargo com For orders please provide an accurate and full postal address Siargo will not ship to P O Boxes or via a third party Please cont...

Страница 24: ...he I2C interface in serial For further information and purchase of the evaluation kit please contact the manufacturer or the sales representative Each converter has a fixed cable that can be directly...

Страница 25: ...communication protocol update Revision A 11 September 2019 o Output definition update product selection code update Revision A 10 April 2019 o Update temperature range Revision A 9 November 2018 o Cal...

Отзывы: