Seite
21
von
32
DESCRIPTION OF THE DEVICE
A
control panel + display
B
NTC-Sensor
C
ON/OFF switch
D
heating panel
START UP
SAFETY INSTRUCTIONS FOR ASSEMBLY
The SHX-heating panel can be mounted on walls or other vertical surfaces.
Please note:
1. The SHX heating panel may only be installed with the wall mounting brackets supplied.
2. Make sure that the wall you mount the panel on can carry the weight of the panel.
3. To avoid overloading the circuit, do not connect the panel to a circuit to which other
devices are already connected.
4. The heater must not be located immediately below a socket outlet.
5. Mount the panel 20-100cm above the floor.
6. Leave a space of at least 50cm to all sides of the device. Leave at least 1-2 meters to
all sides if there are solid or flammable objects.
7. Make sure that there is no material in the immediate surrounding of the heating panel
that can deform or discolour at a temperature above 100°C.
8. In order not to impair the heating efficiency, do not position any furniture or other objects
in front of the heating panel.
9. Never install the cord behind the panel.
HINWEIS
It is recommended that the assembly is carried out in pairs, in order to avoid damaging the
device.