background image

 

Gas Pump Installation 

 

 

Considerations 

When designing a BIB system, take the following points in consideration to ensure long-term 
operation of the pump and maximizing space efficiency.  
 

1.  How many pumps?  

There should be one pump per flavor. More pumps may be needed based on the total flow 

requirements for each flavor. 

2.  Where to mount?  

Each pump is equipped with a mounting bracket and can be mounted in the following ways: 
- Wall mount - Space efficient; maximizes vertical space. 
- Top mounting bar - Space e fficient; easy to relocate and can be pre -assembled. 

- Side of rack - Uses more horizontal space; may shorten distance from BIB to pump. 

3. 

Location of pump/BIBs

  

- Low traffic areas - A key benefit of SHURflo BIB pumps is distance pumping capability. This allows 
the BIB system to be located out of the employee high traffic areas and in a more strategic 
location. 

- Away from high heat - heat can distort the plastic parts of the pump and shorten the shelf life of 
the syrup. If high heat is a factor in where the pumps are to be located, the pumps need to be 

shielded from the heat. If at all possible it would be better to locate the pumps in a different 
location. 

- Outside walk-in cooler- moisture can collect in the control cover and swell poppet seals causing 
the pump to fail. The cooler temperature causes the viscosity of the product to increase making the 
pump to work harder to move the same amount of syrup. 

- In ventilated areas only - high concentrations of CO

2

 can be fatal, since it will displace oxygen 

from non-ventilated areas. If CO

2

 operated BIB pumps are placed in a confined area (such as a 

basement, closet, cooler box, etc.), exhaust fans capable of changing the room air on a continuous 
basis should be used. Another option is to manifold the exhaust ports to the outside. 
 

Guidelines 

 

1.  Mount pump with outlet on top at higher or 

same level as BIB This allows any air on the 

BIB (inlet) side of the pump to float up to the 
pump and pass through the system. Creating 
an installation which avoids trapping air, 

preventing service calls.  

 

2.  Inlet Side - Use only 3/8" I.D. (10mm) Tygon 

or equivalent tubing with a minimum of 1/8" 
(3.2mm) inch wall. Due to the limited vacuum 

the maximum inlet tubing length is 10 ft. 
(3m). Within that distance, a maximum of 5 

ft. (1.5 m) vertical lift is permitted. 

(Note: 

When an ASV is used, the maximum vertical 

lift will be reduced to 3 ft. (1 m).) 

 

 
3.  Label all lines and pumps. To ensure proper 

delivery of syrup to the dispenser, all lines 
should be tied-down using tie-wraps in their 

proper location and clearly labeled. Attention 
to detail will prevent accidental mixing of the 
flavors during BIB changes and will also 

facilitate future servicing.  

 

 

 

Содержание HeavyDuty Advantage BIB 94-360-00

Страница 1: ...uality drink at the dispenser head The above design configuration results in the greatest efficiency and lowest pressure drop every time the dispensing valve open and closes and thus insuring consiste...

Страница 2: ...97 mm Size FLOport 6 0 H x 5 9 W x 4 3 D 152 mm x 150 mm x 110 mm Displacement 3 4 oz 74 cc cycle Suction Lift Activated 20 in Hg 508 m bar wet 25 in Hg 847 m bar Maximum Operating Pressure 85 psi 5...

Страница 3: ...e compressed gas drives the pump and does not come in contact with the syrup The minimum gas pressure is 20 psi 1 4 bar and the maximum is 85 psi 5 8 bar The figures below illustrate the flow of gas a...

Страница 4: ...At equalization the pump stops Sold Out The pump operates only when there is an adequate supply of syrup Vacuum produced by the pump evacuates the syrup within the bag Once the preset vacuum point is...

Страница 5: ...d purging of the liquid outlet lines when the BIB is empty The Shurflo BIB pump ensures drink quality from the first drink to the last The SHURflo pump is compatible with all types of dispensing equip...

Страница 6: ...s Nitrogen or Clean Compressed Air Materials of Construction Polypropylene EPDM Santoprene 316 Stainless Steel Temperature Limits 34 120 F 1 1 49 C Weight 2 lbs 0 9 kg Size 7 9 H x 5 7 W x 3 8 D 171 m...

Страница 7: ...l Specifications Design Two Chamber Double Diaphragm Power Source CO2 gas Nitrogen or Clean Compressed Air Materials of Construction Polypropylene EPDM Santoprene 316 Stainless Steel Temperature Limit...

Страница 8: ...bow 3 8 plastic barb elbow 1 4 plastic barb Tee w check valve none yes 94 366 51 Blue High Altitude H D A syrup pump 3 8 SS barb elbow 3 8 plastic barb elbow 1 4 plastic barb elbow w check valve none...

Страница 9: ...poppet seals causing the pump to fail The cooler temperature causes the viscosity of the product to increase making the pump to work harder to move the same amount of syrup In ventilated areas only h...

Страница 10: ...meters longer than required to provide a service loop This allows the BIB rack to be moved for cleaning or service 5 Oetiker clamps All tubing connections must be secured with stainless steel stepless...

Страница 11: ...Maximum static gas pressure to the pump is 5 8 bar 85 psi minimum is 1 4 bar 20 psi Any time the pressure is changed on the BIB system the brix should be checked to ensure drink quality Notes Flow ra...

Страница 12: ...ates but will not prime dispenser valve open Consult Start up Procedure for proper priming Pump valves have no moisture dry Add water to the inlet port with pump stroking slowly Vacuum leaks at Q D ba...

Страница 13: ...specified To calculate the losses in the system in feet obtained the maximum horizontal tubing length in feet and multiply by 1 instead of 3 Example 1 The tables indicate that heavy soda syrup with 15...

Страница 14: ...Feet Meter Feet Meter 0 5 15 500 152 500 152 500 152 0 75 22 5 500 152 500 152 500 152 1 0 30 453 138 500 152 500 152 1 5 45 212 65 500 152 500 152 2 0 60 102 31 500 152 500 152 2 5 75 64 19 398 121...

Страница 15: ...Beverage Gas Pump ensures quality from the first drink to the last APPLICATION INFORMATION Beverage Gas Pumps are intended for soda syrups and low viscosity concentrates that do not contain solids The...

Страница 16: ...under vacuum SHURflo can recommend several other methods to meet the requirements for a particular installation including Pressurized Inlet Pumps or Accumulators Contact SHURflo for more information I...

Страница 17: ...to the pressure necessary to maintain the desired brix The most efficient gas usage occurs at 40 psi 2 8 bar MAXIMUM static gas pressure to the pump is 85 psi 5 8 bar minimum 20 psi 1 4 bar CAUTION F...

Страница 18: ...of time should be sanitized prior to being placed back in service CAUTION Never apply pressure to the pump s liquid i nlet Pressurized tanks may damage internal components if used to sanitize or purg...

Страница 19: ...s at Q D barb fitting clamps or inlet fitting o ring Excessive amount of air in B I B from improper packaging Air trapped in outlet tubing and or fluid chambers AIR IN INLET AND OR OUTLET TUBING Vacuu...

Страница 20: ...all SHURflo be liable for any indirect incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part This limited warranty covers beverage...

Страница 21: ...once vacuum above 20 in Hg 508 mm Hg is obtained When a new B I B is connected the vacuum drops the pump automatically resumes pumping PUMPING CAPABILITY Due to diversity of both the installations and...

Страница 22: ...22 2 77 23 153 47 Tomato 1 5 1 1 0 29 6 56 17 105 32 1 25 37 0 29 9 50 15 1 5 44 4 13 4 27 8 500 1000 cP FLOW RATE 3 8 10mm I D TUBING 1 2 13mm I D TUBING O J Natural 3 1 0Z SEC CC SEC FEET METER FEE...

Страница 23: ...ants syrup oil rust water etc Air compressors may be used with proper particle filters and moisture separators Air storage tanks should be drained weekly Pumps subjected to contaminated air are not co...

Страница 24: ...concentrate residue Turn OFF CO2 pressure to the pump 3 Prepare 1 gallon 3 8 L of detergent solution in a clean container Mix at the ratio of 1 oz 30 cc of detergent per each gallon of warm water a Pl...

Страница 25: ...date of manufacture The limited warranty will not apply to pumps that were improperly installed misapplied or not suitable with components of other manufactures The limited warranty will not apply to...

Страница 26: ...ired Activated at 20 in Hg 508 mm Hg 34 120 F 1 1 49 C 2 lbs 9 kg Standard plastic 1 4 6mm 90 Optional T or 90 plastic or brass All with internal check valve 3 8 13mm Barb Plastic 90 black Polypropyle...

Страница 27: ...PABILITY Variables within individual systems can affect total pumping distance A gas pumps ability to deliver condiment is limited by the physical demands of the dispensing system Prior to installing...

Страница 28: ...of 10 ft 3M with NO MORE than a 5 ft 1 5M vertical rise Tie wrap all tubing securely to prevent kinks or sags that inhibit performance or cause damage to the pump fittings Use new 1 4 6mm high pressur...

Страница 29: ...25 included with this manual will assure compliance with NSF listed sanitizing requirements for the SHURflo Particulate pump only Consult other equipment manufacturer s instructions for their sanitizi...

Страница 30: ...d to the repair or replacement of the product Warranty replacements will be shipped on a freight allowed basis SHURflo reserves the right to choose the method of transportation Pumps found not defecti...

Страница 31: ...0630 800 854 3218 562 795 5200 FAX 562 795 7564 Shipping 5900 Katella Ave Suite B Cypress CA 90630 SHURflo East 52748 Park Six Court Elkhart IN 46514 5427 800 762 8094 219 262 0478 FAX 219 264 2169 19...

Страница 32: ...ke slowly Once the pump is primed the regulator can be adjusted up 4 Continue dispensing syrup until all the air trapped within the tubing has been purged 5 Once the air has been purged adjust the CO2...