SOS
ASV
PUMP SANITIZING / WINTERIZING
Sanitization of the SHURflo Beverage Gas Pump is required.
The frequency of Sanitization is
dependent on the concentrate type and its manufacturer’s requirements.
Factors, which also affect
the frequency of this procedure, are: temperature, concentrate volatility, facility conditions, installation
and equipment. The sanitizing procedure fulfills a required 10 minute contact time with a 200 ppm
Sodium Hyochlorite solution. Refer to SHURflo Service Bulletin
#
1025 for the N.S.F. listed sanitizing
procedure for the SHURflo pump only
Pumps that are subjected to freezing
(below 32° F [0°C])
must be purged of fluid to prevent damage.
Refer to SHURflo Service Bulletin
#
1025 for complete winterizing procedure.
Refer to the equipment manufacturer’s instructions for sanitizing and winterizing procedure for
carbonators, dispensers and tubing.
NOTE:
Pumps that have been winterized and/or out of service for a period of time should be sanitized
prior to being placed back in service.
CAUTION:
Never apply pressure to the pump’s liquid inlet. Pressurized tanks may damage internal
components if used to sanitize or purge fluid from the pump (operating or not).
BEVERAGE SYSTEM ACCESSORIES
AUTOMATIC SELECTOR VALVE (ASV
Eliminate the chore of replacing B-I-B’s during peak business periods. Teeing B-I-B’s
together still causes them to empty at the same time. An ASV permits multiple B-I-
B’s to be connected to a particular pump. Once the B-I-B
(s)
on one side has
completely emptied the ASV automatically switches sides to full B-I-B’s. An ASV
allows uninterrupted drink dispensing with the ability to replace empty B-I-B’s at
a more convenient time.
SOLD-OUT-SWITCH (SOS
The SOS kit prevents the dispensing of syrup starved drinks by
interrupting water flow at the dispenser valve. An exceptionally useful
feature for lemon lime (clear) sodas and drive-thru windows. The SOS
senses the pressure drop in the syrup line caused by an empty B-I-B and
interrupts power to the valves’ electric solenoid. The SOS automatically
resets with the installation of a full B-I-B.