MAXIMUM HORIZONTAL TUBING
LENGTHS
BY
VISCOSITY
Distances shown are intended as a guideline
only. (cPs.=Centipose)
Distances shown are the results of tests conducted
at 70°F [21°C] ambient with a static pressure of 85
psi. [5.8 bar] to the pump. All distances assume a
dynamic pressure of 35 psi. [2.38 bar] at the
dispenser to maintain brix.
3
8
" I.D. [10mm]
HEAVY SODA
SYRUP
GAS IN
VACUUM TUBING
(min.)
3
8
" I.D. [10mm]
TUBING (min.)
22 ft. [6.7 M]
VERTICAL
FAST FLOW VALVE
1/2 oz./sec [15 mL]
(syrup flow only)
TOTAL TUBING RUN
370 ft. [113M]
Feet:
Take 1
%
of 500 ft.
(500 x 1% )
= 5. Which then is multiplied by
the 22 ft. vertical,
(22 x 5)
= 110 ft.
Subtract this product from
the 500 ft.
(500 - 110)
= 390
.
The results indicate a 390 ft. tubing
run
(horz./vert.)
is possible, while the example only requires a
distance of 370 ft.
Meters:
Take 3
%
of 152
M
(152 x 3%)
= 4.56. Which then is multiplied by
the 6.7
M
vertical,
(4.56 x 6.7)
= 30.5
M
. Subtract this product from
the 152
M
(152 - 30.5)
= 121.5. The results indicate a 121.5
M
tubing run
(horz./vert.)
is possible, while the example only requires
a distance of 113
M
.
NOT E:
Had the example above resulted in a value that was
equal
to, or less
than the necessary total tubing run, consider a larger
I.D. tubing or installation of a pump(s) in series using a
SHURflo Vacuum Regulator.
PUMPS IN SERIES FOR LONG DISTANCES
Long tubing runs or high vertical lift can be achieved by installing
pumps in series. Standard SHURflo Beverage
pumps are not designed to have positive
pressure on the inlet side. The SHURflo
Vacuum Regulating Valve
(VRV)
allows the
pump to receive liquid from a pressurized
source. By positioning a VRV at the inlet of the secondary pump,
incoming pressure is reduced to zero, permitting syrup to be drawn in under vacuum.
SHURflo can recommend several other methods to meet the requirements for a particular installation,
including Pressurized Inlet Pumps or Accumulators. Contact SHURflo for more information.
INSTALLATION GUIDELINES
•
As indicated on the pump, the outlet port is to be mounted up.
•
Pumps are to be mounted at the same level or higher than the B-I-B. The best choice is to have the
pump above the B-I-B.
•
M
AXIMUM INLET
tubing length is 10 ft.
[3
M
]
, with
NO MORE
than a 5 ft.
[1.5
M
]
vertical lift. Use only
3
/
8
"
I.D.
[10mm]
heavy wall
(
1
/
8
" [3mm])
clear, NSF listed vacuum tubing from the B-I-B to the pump.
•
Inlet tubing should not have excessive length. Tubing that is allowed to drape down can trap air in the B-I-B creating a
potential for pump "sold-out" problems.
•
If plumbing multiple B-I-B’s to a pump, B-I-B's should be
"Teed"
side-by-side
horizontally, rather than
one on top of the other
(vertically)
.
•
O
UTLET
tubing from the pump to the dispenser should be high pressure rated and NSF listed. Consult "Pumping
Capability"
(page 2)
for appropriate tubing
I.D.
FLOW RATE
/
SEC.
1
/
4
" I.D.
[6mm]
3
/
8
" I.D.
[10mm]
1
/
2
" I.D.
[13mm]
OZ
.
mL
Feet
Meter
Feet
Meter
Feet
Meter
Diet
Soda
Syrup
(5 cPs.±3)
.5
15
500+
152+
500+
152+
500+
152+
.75
22.5
500
152
500+
152+
500+
152+
1.0
30
453
138
500+
152+
500+
152+
1.5
45
212
65
500+
152+
500+
152+
2.0
60
102
31
500
152
500+
152+
2.5
75
64
19
398
121
500
152
3.0
90
32
9
297
90
500
152
3.5
105
--
--
212
65
500
152
Standard
Soda
Syrup
(20 cPs.±3)
.5
15
500
152
500
152
500+
152+
.75
22.5
133
40
500
152
500+
152+
1.0
30
79
24
388
118
500
152
1.5
45
32
9
193
59
500
152
2.0
60
10
3
127
39
366
112
Heavy
Soda
Syrup
(35 cPs.±3)
.5
15
129
39
500
152
500+
152+
.75
22.5
75
23
345
105
500+
152+
1.0
30
53
16
239
73
500
152
1.5
45
26
8
127
39
425
129
For example:
The chart indicates that heavy syrup with
1
/
2
oz./sec
[15mL]
flow-rate
(per the illustration)
can be sustained
over a horizontal distance of 500 ft.
[152
M
]
when
3
/
8
"
I.D.
[10mm]
tubing is used.