Shure Incorporated
9/16
1.
2.
3.
4.
5.
6.
7.
8.
Plate Mount Preamp Installation
The plate-mounted preamp allows you to mount the preamp in an electical box and use conduit to run cable through ceilings
and walls.
Remove preamp housing by removing two phillips head screws.
Remove knock-out from the hole in the center of the cover plate (if present).
Cut cable to desired hanging length, allowing for a 76 to 101 mm (3 to 4 in.) service loop.
Clamp strain relief around cable and insert strain relief into hole in plate.
Connect cable leads to input terminal block (B = Black, R = Red, S = Shield).
Using professional-quality, two-conductor, shielded microphone cable, thread output cable from outside of preamp
through hole with black bushing.
Connect cable to output terminal block (Pin 2 = +, Pin 3 = –, Shield = S).
Reattach the preamplifier housing.