Страница 2: ...llation of solenoid valve 6 2 5 Installation of sensor of temperature and water level 7 3 System diagram 8 4 Functions operation 9 4 1 Signals on display and function code 9 4 2 Button description 9 4 3 Menu description 10 5 Main functions setup 11 5 1 Time setting 11 5 2 Timing filling and heating with three time sections 11 5 3Pipe insulation belt cable heating function 13 5 4 Booster pump funct...
Страница 3: ...nual functions 15 6 1 Manual water filling 15 6 3 Manual heating 16 7 Protection function 16 7 1Tank high temperature protection function 16 7 2 High temperature protection of collector tube 17 7 3 Tank anti freezing protection 17 7 4 low water pressure protection 17 7 5 Overflow protection 18 7 6 Memory protection 18 7 7 Screen protection 18 7 8 Trouble protection 18 8 Quality Guarantee 19 9 Tech...
Страница 4: ...e make sure that the power supply matches the specifications that controller requires All devices connected to the controller must conform to the technical specifications of the controller All operations on an open controller are only to be conducted cleared from the power supply All safety regulations for working on the power supply are valid Connecting and or all operations that require opening ...
Страница 5: ...fe operation is no longer possible e g visible damage Please immediately take the device out of operation Note ensure that the device can t be accidentally placed into operation 1 3 Signal description Safety indication Safety instructions in the text are marked with a warning triangle They indicate measures which can lead to injury of person or safety risks Operation steps small triangle is used t...
Страница 6: ...ing away the bottom plate Drilling the hole Re hanging the bottom plate on screw Fixing bottom plate with screw 2 2 Power connection Depending on the type of installation the cables may enter the device through the rear hole of the case or the base side hole of the case Notes the flexible wire must be fastened to the case using the strain relief clamps provided 2 3 Terminal port connection Before ...
Страница 7: ...gned for the solenoid valve of water filling output power is DC12V wire connection is not positive and negative difference With Auxiliary electrical heating the user must install the leakage protector himself Input ports Sensor of water temperature and water level of the water tank B03 Port 1 connect red wire 12V Port 2 connect white wire COM Port 3 connect black wire GND 2 4Installation of soleno...
Страница 8: ...n protection and prevent broken damage from freezing or aging of body of solenoid valve It is prohibited to use a wrench worked on the coil wire and plastic parts to ensure no damaged during installation and no torsion effect positioned on the solenoid valve it is not allowed to install valve compulsively when tow connectors are not aligned Two core wire is used for connection with solenoid valve ...
Страница 9: ...e customer does not specify anything we will follow the factory default configuration a Side mounted sensor Factory default configuration see the picture 1 b Top mounted sensor Need to be specified in order see the picture2 2 To avoid the measuring error or damage the sensor sensor of temperature and water level must not touch or close to the e heater tube 3 System diagram Note this diagram is onl...
Страница 10: ... and related parameters of the controller 4 1 Signals on display and function code LCD display screen 4 2 Button description Buttons layout on the controller Button description Water Loading button water filling manually HEAT button heating manually SET button access the menu or activate the set value ESC button confirm the setting value and ESC or return to the previous menu button increase adjus...
Страница 11: ...on S SW 2 if without any operate during 3s the controller works back to normal work interface 4 3 Menu description Main functions menu for users Code Main menu Code Submenu Default value Description Clock Clock Time Water Timing water filling Time Water 03 00 50 Time and water level of the 1st time water filling Time Water 09 00 100 Time and water level of the 2nd time water filling Time Water 16 ...
Страница 12: ...heating of system and it can be triggered automatically at preset time by preset temperature Within a preset time section when the temperature of tank drops below the preset switch on temperature of this function electrical heater starts to work when temperature rises to the preset switch off temperature electrical heater is stopped When water level is lower than 50 during a heating time section t...
Страница 13: ...lling Time Water 03 00 50 00 00 23 59 20 100 Time and water level of the 1st time water filling Time Water 09 00 100 00 00 23 59 20 100 Time and water level of the 2nd time water filling Time Water 16 00 100 00 00 23 59 20 100 Time and water level of the 3rd time water filling Time Heat Timing heating Time Heat 04 00 50 00 00 23 59 0 95 Time and temperature of the1st time water heating Time Heat 1...
Страница 14: ...range 0 90 o C Press SET or ESC button to confirm the setting Repeat above steps to set the time and temperature of the second and the third of timing heating Time Heat and Time Heat 5 3Pipe insulation belt cable heating function Function Description After switch on the belt cable heating default R2 heating for 10mins which can t be set stop for 30 minutes stop time adjustment range 0 90 minutes T...
Страница 15: ...0Mins default is 3mins Press ESC button or wait for 6s to activate the function and Hot water circulation icon blink on the screen Hold press CYCLE button for 3s to deactivate the function immediately Note 1 No matter one of the three Booster pump or Belt cable heating or Hot water circulation needs to occupy the output R2 So one of the functions is on the other two functions are automatically off...
Страница 16: ...ding button for 3 seconds to trigger compulsive water filling function countdown 8 minutes countdown time and water level of 0 20 50 80 and 100 displays on the screen alternatively Press Water Loading button again to stop the compulsive water filling function 5 10 Factory reset manually function Through this function it is possible to recover all parameters to the factory set Setup steps Under pow...
Страница 17: ... the function Press HEAT button temperature 60 o C displays on the screen Press button to adjust the desired temperature adjustable range 0 o C 80 o C factory set is 60 o C Press HEAT or ESC button or wait for 6 seconds to confirm the setting heater starts to work and manual heating signal blinks on the screen Press HEAT again to cease the manual heating function Note manual heating can only heat ...
Страница 18: ...zing of collector tube tank when controller measures the tank temperature drops to only 3 o C factory set not adjustable controller will trigger the electrical heater to heat tank until its temperature rises to 7 o C and then tank anti freezing function is deactivated automatically When anti freezing signal blinks it indicates anti freezing function is running 7 4 low water pressure protection Fun...
Страница 19: ...r supply 7 6 Memory protection In case power failure occurs controller keeps the parameter settings unchanged 7 7 Screen protection When no any press on button for 5 minutes screen protection is activated automatically and LED backlight is dimmed by light Through press any button to light LCD lamp again 7 8 Trouble protection Error code Display status Error description E0 Temperature zone displays...
Страница 20: ...emperature measuring 0 100 o C Inputs temperature and water level sensor Outputs 3electromagnetic relays Ambient temperature 10 o C 50 o C Water proof grade IP40 10 Delivery list Controller 1piece User manual 1piece Sensor of water temperature and water level with cable of 20m 1piece Solenoid valve 1piece Accessories 1bag 10A power cable 1piece 88 8 o C Temperature zone displays 88 8 oC E7 E7 and ...