Problem
Probable Cause
Remedy
Gun will not ignite
The POL excess check
valve has not fully opened.
Turn on propane tank valve and wait
10 seconds or until the needle on the
regulator has reached the factory setting
of 22 PSI. An audible “click” will be
heard when the hose has fully
pressurized with gas.
Clogged orifice
Remove and clean with compressed air.
Clogged fuel line
Remove and clean with compressed air.
Clogged pump body
Remove and clean with compressed air.
Clogged hose assembly
Disconnect and clean with
compressed air.
Combustor turns
glowing red
Low pressure from tank
Increase pressure from tank or
replace tank.
Extremely large flame
Wrong fuel type
Do not use a fork truck tank; only
vapor withdrawal tanks like a BBQ tank.
Tank, regulator or hose
fittings have iced up.
Low pressure from tank
Increase pressure on regulator or
change to a new tank.