![SHOWTEC The Moustache Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/showtec/the-moustache/the-moustache_manual_1260539008.webp)
7
Ordercode: 75120/75121
The Moustache
Warnings
CAUTION
This product is not intended to be used as fall protection!
CAUTION
The maximum working load limit for the Moustache is 100 kg.
Do not exceed this rating.
CAUTION
Do not use the Moustache to lift people or to lift loads above people!
Maintenance
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year or more frequently if used intensively.
The following points have to be considered during the inspection:
01)
All screws used for installing the device or parts of the device have to be tightly connected and
must not be corroded.
02)
There may not be any deformations on housings, fixations and installation spots.
03)
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
The Moustache requires almost no maintenance. However, you should keep the clamp clean. Wipe with
a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents.
●
All inspections and any actions taken, must be documented in writing.
●
After using the Moustache, any dirt needs to be removed.
●
Always store the Moustache in a dry environment, to prevent corrosion.
●
Repairs may only be carried out by experts that are authorized in writing by Highlite International.
●
In case that repairs or modifications are carried out by unauthorized personnel, the warranty and
product liability will become void. Only use original parts for repairs.
Inspection & Maintenance Intervals
The following inspection and maintenance intervals apply for normal use. In case of use in harsh
environment, such as regular deployment at full load or use in a hot / dusty or otherwise aggressive
environment, the indicated intervals should be shortened.
When
commissioning
Daily
inspection
1
st
maintenance
after 3 months
Inspection /
maintenance
annually
Check screw / bolt connections
X
X
X
X
Check for any deformations
X
X
X
X
Regular inspection by an expert
X
Regular Inspections
Regardless of national rules in the country of use, the Moustache has to be inspected by an expert, at
least once a year.
●
In case of heavy/frequent usage, the inspection and maintenance intervals need to be more
regular.
●
Check the Moustache
carefully, to make sure that there are no unusual noises that could indicate
faults or excessive wear.
●
Make sure all bolts and nuts are tight and check presence and legibility of the type plate.