SHOWTEC The Moustache Скачать руководство пользователя страница 8

 

  

 

 

   

 

Ordercode: 75120/75121 

The Moustache 

Warnings 

 

 

CAUTION 

This product is not intended to be used as fall protection! 

 

 

 

CAUTION 

The maximum working load limit for the Moustache is 100 kg. 

Do not exceed this rating. 

 

 

 

CAUTION 

Do not use the Moustache to lift people or to lift loads above people! 

 

 
 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year or more frequently if used intensively
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

 
The Moustache requires almost no maintenance. However, you should keep the clamp clean. Wipe with 
a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents. 
 

 

All inspections and any actions taken, must be documented in writing. 

 

After using the Moustache, any dirt needs to be removed. 

 

Always store the Moustache in a dry environment, to prevent corrosion. 

 

Repairs may only be carried out by experts that are authorized in writing by Highlite International. 

 

In case that repairs or modifications are carried out by unauthorized personnel, the warranty and 
product liability will become void. Only use original parts for repairs. 

 
 

Inspection & Maintenance Intervals 

The following inspection and maintenance intervals apply for normal use. In case of use in harsh 
environment, such as regular deployment at full load or use in a hot / dusty or otherwise aggressive 
environment, the indicated intervals should be shortened. 
 

 

When 

commissioning 

Daily 

inspection 

1

st

 maintenance 

after 3 months 

Inspection / 

maintenance 

annually 

Check screw / bolt connections 

Check for any deformations 

Regular inspection by an expert 

 

 

 

 
 

Regular Inspections 

Regardless of national rules in the country of use, the Moustache has to be inspected by an expert, at 
least once a year. 

 

In case of heavy/frequent usage, the inspection and maintenance intervals need to be more 
regular. 

 

Check the Moustache

 

carefully, to make sure that there are no unusual noises that could indicate 

faults or excessive wear. 

 

Make sure all bolts and nuts are tight and check presence and legibility of the type plate. 

 

 

Содержание The Moustache

Страница 1: ...The Moustache V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 75120 75121 MANUAL ENGLISH...

Страница 2: ...Determinations 3 Rigging 3 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Installation 5 Setup and Operation 6 Inspection Before Use 6 Installing the Moustache 6 Warnings 7 Mainte...

Страница 3: ...the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the device are not subject to warranty This device contains no user ser...

Страница 4: ...year after date of purchase Operating Determinations This device is not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without...

Страница 5: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 6: ...le for the Pro30 Step Pro30 Triangle Pro30 Square Truss For extra stability use the Fix Clamp 75122 silver or 75123 black Working load limit WLL 100 kg Bolt M8 35 mm Tube diameter 48 51 mm Material Me...

Страница 7: ...checked in advance CAUTION Before installation operators must be instructed and fully understand the safe use of the equipment Before each use the Moustache has to be inspected on the following points...

Страница 8: ...irt needs to be removed Always store the Moustache in a dry environment to prevent corrosion Repairs may only be carried out by experts that are authorized in writing by Highlite International In case...

Страница 9: ...iameter 48 51 mm Material Metal Color Black 75120 Silver 75121 Dimensions 331 x 36 x 195 mm LxWxH Weight 1 32 kg Operation Working load limit WLL 100 kg Bolt M8 35 mm Design and product specifications...

Страница 10: ...9 Ordercode 75120 75121 The Moustache Notes...

Страница 11: ...10 Ordercode 75120 75121 The Moustache...

Страница 12: ...2019 Showtec...

Отзывы: