background image

 

 
 
 
 
 
 
 
 
 
 

 

 

Performer 2000 Fresnel DDT MKII  V2 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Ordercode: 33037 

MANUAL 

ENGLISH 

Содержание Performer 2000 Fresnel DDT MKII V2

Страница 1: ...Performer 2000 Fresnel DDT MKII V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33037 MANUAL ENGLISH...

Страница 2: ...rmers DMX Control 14 Fixture Linking 15 Data Cabling 15 Control Panel 16 Control Mode 16 DMX Addressing 16 Menu Overview 17 Main Menu Options 18 1 Static Color 18 2 Run Mode 19 3 Power Mode 19 4 Addre...

Страница 3: ...2 Ordercode 33037 Performer 2000 Fresnel DDT MKII Troubleshooting 25 No Light 25 No Response to DMX 25 Product Specifications 27 Dimensions 28 Notes 29...

Страница 4: ...Performer 2000 Fresnel DDT MKII 1 Powercon power cable 1 5m 1 color frame 1 safety cable User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor t...

Страница 5: ...leave various parts of the packaging plastic bags polystyrene foam nails etc within children s reach as they are potential sources of danger Never use a LED strip in sealed or hot places Always mount...

Страница 6: ...d out by a qualified technician WARRANTY Till one year after date of purchase Note WARRANTY on batteries is only 6 months after date of purchase When your battery remains flat after fully charging or...

Страница 7: ...rvicing the device always make sure that the area below the installation site is secured and that there are not any unauthorized people around The device can be mounted to any kind of truss with a cla...

Страница 8: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Страница 9: ...rendering 90Ra Color temperature 3100K Dimmer 0 100 Dim curve Dimm4 technology 4 presets Strobe 0 20Hz Motorized zoom 13 41 Control modes Stand alone Master Slave DMX 512 Connections 3 pin 5 pin XLR...

Страница 10: ...with inclination screw 08 Heat sink bracket 09 Lens plate 10 Lens frame 11 Collecting lens 12 LED board 13 Thermal switch holder 14 Cooling fan 15 Cooling fan frame 16 Air intake grill 17 Motor 18 Mo...

Страница 11: ...power connector 100 240V IN 30 3 pin DMX signal connector IN 31 5 pin DMX signal connector IN 32 3 pin DMX signal connector OUT 33 5 pin DMX signal connector OUT 34 PowerCON power connector 100 240V O...

Страница 12: ...s make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supp...

Страница 13: ...Performer 2000 Fresnel DDT MKII Setting the angle 01 Loosen the adjustment screw do not remove them 02 Tilt the fixture to the desired position 03 Tighten the adjustment screw to secure the fixture i...

Страница 14: ...Performers Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin 5 pin XLR cable to connect the Performer The pin...

Страница 15: ...ig 07 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug elec...

Страница 16: ...fixtures on a Powercon link 6 units 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or const...

Страница 17: ...e DMX address of the third Performer should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control each Performer correctly If two or more Performers are ad...

Страница 18: ...17 Ordercode 33037 Performer 2000 Fresnel DDT MKII Menu Overview...

Страница 19: ...n set the static color and the zoom function 01 While in the main menu press the UP DOWN buttons to choose STATIC 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to toggle betw...

Страница 20: ...ions may occur When the power supply reaches 80 of the nominal voltage and a DMX signal is received the Performer will be controlled by DMX When the power supply is below 80 of the nominal voltage and...

Страница 21: ...RATE Refresh rate 6 1 Safety Key 01 When the display shows KEY press the ENTER button to open the menu 02 Press the UP DOWN buttons to toggle between ON and OFF to activate deactivate the safety lock...

Страница 22: ...hrough the 3 channel modes UNO 1 channel mode DOS 2 channel mode STD P 5 channel mode 6 7 Save DMX Blackout 01 When the display shows DMX ERROR press the ENTER button to open the menu 02 Press the UP...

Страница 23: ...er to access the menu Press the buttons in the following order UP DOWN UP DOWN and press the ENTER button to confirm 04 You can choose between Pose1 or Pose2 05 Press the ENTER button again to open th...

Страница 24: ...mer 0 255 0 100 dimmer Channel 2 Fine dimmer CH1 must be open 0 255 Fine dimmer adjustment Channel 3 Strobe CH1 must be open 0 9 Strobe OFF 10 99 Strobe ON from low to high frequency 100 109 Strobe OF...

Страница 25: ...show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue The Performer 2000 Fresnel DDT MKII requires almost no maintenance However you should keep...

Страница 26: ...for replacing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Performer as this may damage the unit...

Страница 27: ...connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on t...

Страница 28: ...0 Dimming curve Dimm4 technology 4 presets Strobe 0 20Hz Peak intensity 128880cd Color rendering 90Ra Color temperature 3100K Refresh rate 600Hz 25000Hz Housing Die cast aluminium flame retardant plas...

Страница 29: ...28 Ordercode 33037 Performer 2000 Fresnel DDT MKII Dimensions...

Страница 30: ...29 Ordercode 33037 Performer 2000 Fresnel DDT MKII Notes...

Страница 31: ...30 Ordercode 33037 Performer 2000 Fresnel DDT MKII...

Страница 32: ...2019 Showtec...

Отзывы: