background image

 

  

 

 

   

 

Ordercode: 40225 

Mini Q-Strobe 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always check if the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

PHASE

 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always properly connected to the earth! 

 

Improper installation can cause serious injuries and/or damage of property! 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
agreed otherwise in writing. 
Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of 
the invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement from which the obligation is resulting.  
 

 

Содержание Mini Q-Strobe

Страница 1: ...Mini Q Strobe V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40225 MANUAL ENGLISH...

Страница 2: ...ructions 2 Operating Determinations 4 Rigging 4 Connection with the mains 5 Return Procedure 5 Claims 5 Description of the device 6 Features 6 Frontside 6 Backside 7 Installation 7 Set Up and Operatio...

Страница 3: ...shipment includes Showtec Mini Q Strobe with a fixed CEE 7 16 Europlug 0 75 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has t...

Страница 4: ...r is open Always allow free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord by...

Страница 5: ...hers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried...

Страница 6: ...UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addres...

Страница 7: ...a 10W compact strobe fixture Input voltage 220 240V AC 50 60Hz Power consumption 10W Strobe frequency 1 15 flashes sec Housing Flame retardant plastic Dimensions 145 x 165 x 170 mm LxWxH Weight 0 5 kg...

Страница 8: ...Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification volt...

Страница 9: ...brush and vacuum cleaner Make sure connections are thoroughly dry before supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs...

Страница 10: ...cts Strobe frequency 1 15 flashes sec Housing Flame retardant plastic Connections CEE 7 16 Europlug power cable IN Max ambient temperature ta 5 40 C Max housing temperature tB 80 C Minimum distance Mi...

Страница 11: ...10 Ordercode 40225 Mini Q Strobe...

Страница 12: ...2017 Showtec...