SHOWTEC galactic b300 Скачать руководство пользователя страница 12

10 

 

Multiple Galactic (

DMX Control

)

 

1.

 

Fasten the 

effect light

 onto firm trussing 

Leave at least 1 meter on all sides for air circulation. 

2.

 

Always use a safety cable (ordercode 70140 / 70141). 

3.

 

Use a 3-p XLR cable to connect the Galactic lasers.

 

4.

 

Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket 
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.

 

5.

 

Supply electric power: Plug the end of the mains power cord into proper electric power supply 
sockets. Do so for all units and the controller. 

 

 

Multiple Galactics Set Up

 

 

 
 
 
 
 
 
 
 

     Max. 30 Galactics

 

 

Fig. 4

 

 

 

Note : Link all DMX cables and set dip switches before connecting electric power 

 

6.

 

Do not supply power before the whole system is set up and connected properly. Design your show 
according to your DMX controller functions. See page 12 and 13 for more about DMX programming.

 

 

Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.   
 
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of Galactics on a DMX data link: 30 fixtures 
 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. 

bal. XLR/M 3 p. > XLR/F 3 p.  

Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

 

DAP Audio cable f

or the demanding user with exceptional audio-qualities and connector made by  

Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

Содержание galactic b300

Страница 1: ...Galactic B300 V2 ORDERCODE 51320 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...nd manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec...

Страница 3: ...ne Galactic Sound control 9 Multiple Galactics Master Slave control 9 Multiple Galactic DMX Control 10 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overvi...

Страница 4: ...e of this device have to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult...

Страница 5: ...ed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the...

Страница 6: ...ufacturing Label Identification Laser Classification Class IIIB Cooling TE Cooling Laser medium LD GaAIAs wavelength 450 nm Blue Output 300mW CAUTION The use of corrective eye wear or optics for viewi...

Страница 7: ...installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Galactic is lowered from the ceiling or high joists professional trussing systems have to be u...

Страница 8: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 9: ...GaAIAs wavelength 405 nm Control Music DMX Auto Master Slave 3 pin DMX In and 3 pin DMX Out Clear LCD display for all settings Compact strong metal housing Music controlled via built in microphone 8...

Страница 10: ...the device to the main power supply The device can be music controlled by its built in microphone The Interlock plug remote plug and safety keys are included in the box The interlock is the included i...

Страница 11: ...ic Please see page 12 for more information about the sound control options Multiple Galactics Master Slave control 1 Fasten the effect light onto firm trussing Leave at least 1 meter on all sides for...

Страница 12: ...ing mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be...

Страница 13: ...ddress of the third Galactic should be 9 8 17 etc Please be sure that you don t have any overlapping channels in order to control each Galactic correctly If two or more Galactic s are addressed simila...

Страница 14: ...Use the Up Down buttons to select the required address from 3 Use the ENTER button to store your setting 2 Slave Mode With this menu you are able to set the device as a slave device 1 Press the FUNC...

Страница 15: ...slow to fast 210 255 Zoom In and Out from slow to fast Channel 4 Y axis Rolling 0 127 0 359 degree fixed Y Axis rolling 128 191 Clockwise rolling from slow to fast 192 255 Counterclockwise rolling fro...

Страница 16: ...5 192 199 008 015 072 079 136 143 200 207 016 023 080 087 144 151 208 215 024 031 088 095 152 159 216 223 032 039 096 103 160 167 224 231 040 047 104 111 168 175 232 239 048 055 112 119 176 183 240 24...

Страница 17: ...own or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product sp...

Страница 18: ...efective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination...

Страница 19: ...ontrol Music DMX Auto Master Slave DMX controlled 3 pin DMX In and 3 pin DMX Out Clear LCD display for all settings Compact strong metal housing Music controlled via built in microphone 8 DMX Channels...

Страница 20: ......