background image

 

 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 

 

QubiQ S1500 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Product code: 61061 

USER MANUAL 

ENGLISH 

V1 

Содержание 61061

Страница 1: ...QubiQ S1500 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 61061 USER MANUAL ENGLISH V1...

Страница 2: ...ce Non observance of the instructions in this user manual may result in serious injuries and damage of property 2022 Showtec All rights reserved No part of this document may be copied published or oth...

Страница 3: ...5 Rigging 15 Connecting to Power Supply 17 Power Linking of Multiple Devices 17 5 Setup 18 Warnings and Precautions 18 Stand alone Setup 18 DMX Connection 18 DMX 512 Protocol 18 DMX Cables 19 DMX Link...

Страница 4: ...39 DMX Operation 40 DMX Channels 40 7 Troubleshooting 41 8 Maintenance 42 Safety Instructions for Maintenance 42 Preventive Maintenance 42 Basic Cleaning Instructions 43 Cleaning the Fluid Pipes 43 Co...

Страница 5: ...may lead to hazardous situations and result in injuries and material damage This device is not suitable for households Any other use not mentioned under intended use is regarded as non intended and i...

Страница 6: ...uation which if not avoided may result in minor or moderate injury Attention Indicates important information for the correct operation and use of the product Important Read and observe the instruction...

Страница 7: ...and all screws are tightly fastened Disconnect the device from electrical power supply before service and maintenance and when the device is not in use DANGER Electric shock caused by short circuit Th...

Страница 8: ...uch as perfume and alcohol to the fog fluid Operate the device only with the fluids recommended in this user manual CAUTION Risk of health problems Operate the device only with the fluids recommended...

Страница 9: ...portation do not switch it on immediately Let the device reach room temperature before switching it on otherwise it may be damaged by the formed condensation If the device fails to work properly disco...

Страница 10: ...aler for more information Instructed persons have been instructed and trained by a skilled person or are supervised by a skilled person for specific tasks and work activities associated with the insta...

Страница 11: ...ity is seamlessly adjustable from 0 100 Not only can you control the fogger manually but also via DMX or included timer remote control The QubiQ S1500 is reliable since it can provide a continuous out...

Страница 12: ...LED display with Menu buttons 08 ON OFF 09 Ground earth connection 10 Pro power connector Gray OUT 11 Pro power connector Blue IN 12 Fuse F8AL 250 V 13 3 pin DMX signal connector OUT 14 3 pin DMX sign...

Страница 13: ...biQ S1500 Product code 61061 Remote Control Fig 04 16 5 pin DIN connector with 3 5 m cable 17 Control Wheel 18 Blue SETUP Button 19 Red PLUS CONTI 20 Yellow MINUS TIMER Button 21 Green ENTER MANUAL Bu...

Страница 14: ...dy output till tank runs out of liquid Operation and control Control DMX 512 Manual Remote Timer DMX channels 1 channel Control panel LED display and buttons Connections Power connections Pro power co...

Страница 15: ...14 QubiQ S1500 Product code 61061 Dimensions Fig 05...

Страница 16: ...e used only indoors The device can be mounted to a truss or other rigging structure in any orientation The minimum distance to other objects must be bigger than 0 8 m The minimum distance between the...

Страница 17: ...evice cannot move freely 02 Secure the device with a secondary suspension for example a safety cable Make sure that the secondary suspension can hold 10 times the weight of the device If possible the...

Страница 18: ...supports power linking Power can be relayed to another device via the power OUT connector Note that the input and the output connectors have different designs one type cannot be connected to the other...

Страница 19: ...more devices set in a DMX mode The QubiQ S1500 has 3 pin DMX signal IN and OUT connectors The pin assignment is as follows 3 pin pin 1 ground pin 2 pin 3 Devices on a serial data link must be daisy ch...

Страница 20: ...ur own DMX cables make sure that you connect the pins and wires correctly as shown in Fig 07 Fig 07 DMX Linking To connect multiple devices on one DMX data link follow the steps below Use a 3 pin DMX...

Страница 21: ...low Set the starting address of the 1st device on the data link to 1 001 02 Set the starting address of the 2nd device on the data link to 2 002 as 1 1 2 03 Set the starting address of the 3rd device...

Страница 22: ...on intended and incorrect use Attention Power supply Before connecting the device to the power supply make sure that the current voltage and frequency match the input voltage current and frequency spe...

Страница 23: ...e fluids recommended in this user manual Make sure that you do not to exceed the maximum fluid level Do not overfill To fill the tank follow the steps below Lift the small ring on top of the device to...

Страница 24: ...k as shown in Fig 14 Fig 13 Fig 14 Place the fluid tank on a flat service near the device as shown in Fig 15 Use a funnel to pour the fog fluid into the tank as shown in Fig 16 Fig 15 Fig 16 Fill the...

Страница 25: ...17 Fig 18 Put the lid back on the device as shown in Fig 19 Close the service lid as shown in Fig 20 Fig 19 Fig 20 Wait for the device to heat up This will take a maximum of 3 minutes Notes Do not all...

Страница 26: ...tank follow the steps below Lift the small ring on top of the device to open the service lid as shown in Fig 21 Open the service lid as shown in Fig 22 Fig 21 Fig 22 Remove the service lid as shown in...

Страница 27: ...k as shown in Fig 26 Fig 25 Fig 26 Place the fluid tank on a flat service near the device as shown in Fig 27 Use a funnel to pour the fog fluid from the tank into original fog fluid jerry can as shown...

Страница 28: ...fluid tank as shown in Fig 30 Fig 29 Fig 30 Put the lid back on the device as shown in Fig 31 Close the service lid as shown in Fig 32 Fig 31 Fig 32 Notes Do not allow the fog liquid to become contam...

Страница 29: ...will keep displaying this Warning message Make sure you fill the entire tank let the device reheat and then manually start fogging This will take a few seconds until the completely emptied lines are...

Страница 30: ...t the Interval volume in Interval menu See 6 7 4 3 Interval on page 32 for more information Adjust the Duration volume in Duration menu See 6 7 4 4 Duration on page 33 for more information Notes You c...

Страница 31: ...are version and the temperature Before you are able to see the main menu or change settings you have to wait until the device is fully heated The display will show Before you are able to see the main...

Страница 32: ...always has priority over manual operation with the control panel on the device You are not able to use the buttons on the device when the remote is plugged in Do not connect the DMX cables and the rem...

Страница 33: ...MX address Press the UP DOWN buttons to set the desired DMX address The adjustment range is 001 512 Output Volume In this menu you can manually set the output volume Press the UP DOWN buttons to set t...

Страница 34: ...the Fluid Sensor Press the UP DOWN buttons to select one of the following 2 options Yes Sensor is on NO Sensor is off Restore Default In this menu you can restore the default factory settings Press th...

Страница 35: ...ange the settings To operate the device manually as a stand alone device Adjust the output volume in Output Vol menu See 6 8 4 2 Output Volume on page 38 for more information Adjust the Interval volum...

Страница 36: ...tup Scroll through the Menu 18 Plus Conti Increase value Continuous output 19 Minus Timer Decrease value Timer 20 Enter Manual Enter Manual Fog output Start up Remote Control Upon start up the display...

Страница 37: ...e control panel on the device You are not able to use the buttons on the device when the remote is plugged in Menu Overview Remote Control The main menu has the following options Press the UP DOWN but...

Страница 38: ...nu 03 Press the UP DOWN buttons or turn the CONTROL WHEEL to increase decrease the values RMTVOL Set the intensity of the output volume The adjustment range is 1 100 from low to high output See 6 8 4...

Страница 39: ...s or turn the CONTROL WHEEL to increase decrease to set the desired duration of your fog output The adjustment range is 1 999 sec Interval In this menu you can set the fog interval Press the UP DOWN b...

Страница 40: ...p fogging until the tank is completely empty Timer Interval In this menu you can set the fog timer and determine the interval Press the yellow MINUS TIMER button or press the CONTROL WHEEL to start yo...

Страница 41: ...s will take a maximum of 3 minutes When the device is not 100 heated you cannot view the menu or change the settings Set the DMX starting address of the device in Address menu See 5 3 4 DMX Addressing...

Страница 42: ...a link connection Examine connections and cables Correct poor connections Repair or replace damaged cables The data link is not terminated with a 120 termination plug Insert a termination plug in the...

Страница 43: ...least 15 minutes before servicing or cleaning Preventive Maintenance Attention Before each use examine the device visually for any defects Make sure that All screws used for installing the device or p...

Страница 44: ...Cleaning the Fluid Pipes The device must be cleaned periodically from the fog fluid residues After every 40 hours of continuous operation it is recommended to run a cleaning solution composed of 80 d...

Страница 45: ...circuit or incorrect electrical power supply may cause a fuse to burn out If the fuse burns out the device will not function anymore If this happens follow the steps below Disconnect the device from...

Страница 46: ...s empty before storing the device See 6 4 Emptying the Tank after operation on page 25 for more information Clean the device before storing Follow the cleaning instructions in chapter 8 2 1 Basic Clea...

Страница 47: ...1 QubiQ S1500 Product code 61061...

Страница 48: ...2022 Showtec...

Отзывы: