41
QubiQ S1000
Product code: 61060
7.
Troubleshooting
This troubleshooting guide contains solutions to problems which can be carried out by an ordinary
person. The device does not contain user-serviceable parts.
Unauthorized modifications to the device will render the warranty void. Such modifications may result in
injuries and material damage.
Refer servicing to instructed or skilled persons. Contact your Highlite International dealer in case the
solution is not described in the table.
Problem
Probable cause(s)
Solution
The device does not
function at all
No power to the device
●
Check if power is switched on and cables
are plugged in
Main fuse is blown
●
Replace the fuse. See 8.3.1. Replacing
the Fuse on page 44
The device responds
erratically
The factory settings of the device
are changed
●
Reset the device’s parameters to the
default factory settings. See 6.7.4.6.
Restore Default on page 33
The device does not
respond to DMX
control
The controller is not connected
●
Connect the controller
The signal is reversed. The 3-pin/5-pin
DMX OUT of the controller does not
match the DMX IN of the device
●
Install a phase-reversing cable between
the controller and the device
The controller is defective
●
Try using another controller
The device responds
erratically to DMX
control
Bad data link connection
●
Examine connections and cables.
Correct poor connections. Repair or
replace damaged cables
The data link is not terminated with a
120 Ω termination plug
●
Insert a termination plug in the DMX OUT
connector of the last device on the link
Incorrect addressing
●
Check address settings and correct, if
necessary
In case of a setup with multiple
devices, one of the devices is
defective and disturbs data
transmission on the link
●
To find out the defective device, bypass
one device at a time until normal
operation is restored
No fog output
Device is too hot
●
Allow device to cool down.
●
Make sure that air vents are not blocked.
The device is damaged
●
Disconnect the device and contact your
Highlite International dealer
The power supply settings do not
match local AC voltage and
frequency
●
Disconnect the device. Check the
settings and correct, if necessary
The fluid pipes or the fog output
nozzle (06) are clogged.
●
Clean the fluid pipes. See 8.2.1.
Basic
Cleaning Instructions and 8.2.2.
Cleaning the Fluid Pipes on page 43
Incompatible fog fluid
●
Use the recommended fog fluid. See 6.2.
Recommended Fog Fluid on page 21
Fog output nozzle is
sputtering
Incompatible fog fluid
●
Use the recommended fog fluid. See 6.2.
Recommended Fog Fluid on page 21
Device does not
function correctly.
(Error message: Fluid
Lack!)
Tank is empty
●
Fill the tank. See 6.3. Filling the Tank on
page 22
Fluid pipes are empty
●
Restart the device. See 6.5. Restarting the
Device after Running the Tank empty on
page 28