Do not confuse this CFM recommendation with the rating
of the dust collector. To determine the CFM at the dust
port, you must consider these variables: (1) CFM rating of
the dust collector, (2) hose type and length between the
dust collector and the machine, (3) number of branches
or wyes, and (4) amount of other open lines throughout
the system. Explaining how to calculate these variables
is beyond the scope of this manual. Consult an expert or
purchase a good dust collection “how-to” book.
This. machine. creates. substantial. amounts. of. dust.
during.operation..Breathing.airborne.dust.on.a.regu-
lar.basis.can.result.in.permanent.respiratory.illness..
Reduce.your.risk.by.wearing.a.respirator.and.captur-
ing.the.dust.with.a.dust.collection.system.
To.help.prevent.material.build-up.from.
obstructing. dust. chute. and. negatively.
impacting.cutterhead.operation,.always.
remove.dust.port.if.operating.machine.
without.a.dust.collection.system.
Figure.15.
Dust port installed on jointer.
Figure.16.
Dust port connected to dust
collection system.
-18-
Model W1876 (For Machines Mfd. Since 7/20)
SE
TU
P
Recommended.CFM.at.Dust.Port:................. 150.CFM
Dust.Collection
Tools.Needed.
Qty
Dust Collection System ........................................1
Dust Hose 2
1
⁄
2
" ..................................................1
Hose Clamps 2
1
⁄
2
" ...............................................2
To.install.dust.port.on.jointer,.do.these.steps:
1.
Remove (4) button head cap screws from dust chute
on left side of jointer base.
2.
Place dust port over dust chute and install (4) button
head cap screws removed in
Step.1
to secure dust
port in place (see
Figure.15
).
Note:
To help prevent material build-up from
obstructing dust chute and negatively impacting
cutterhead operation, DO NOT install dust port if
operating machine without a dust collection system.
To.connect.a.dust.collection.hose,.do.these.steps:
1.
Fit a 2
1
⁄
2
" dust hose over the dust port, as shown in
Figure.16
, and secure in place with a hose clamp.
2.
Tug the hose to make sure it does not come off.
Note:
A tight fit is necessary for proper
performance.
Dust Port
Button
Head Cap
Screw
(1 of 4)