Operation Manual Shodex SUGAR KS-800 series 

 

Version 2020 

 

 

 

 
 
 

Operation Manual 

Shodex™ 

SUGAR

 KS-800 series 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Europe, Middle East, Africa, Russia 
www.shodex.de 

Sales Office: 
Showa Denko Europe GmbH 
Shodex Business 
Konrad-Zuse-Platz 3 
81829 Munich 
Germany 
 

Technical Support: 

[email protected] 
+49 (0)89 / 93 99 62 37 
 

Quotes and Orders: 

[email protected] 
+49 (0)89 / 93 99 62 34 

Содержание SUGAR KS-800 Series

Страница 1: ... Shodex SUGAR KS 800 series Europe Middle East Africa Russia www shodex de Sales Office Showa Denko Europe GmbH Shodex Business Konrad Zuse Platz 3 81829 Munich Germany Technical Support info shodex de 49 0 89 93 99 62 37 Quotes and Orders order shodex de 49 0 89 93 99 62 34 ...

Страница 2: ...r ion Particle size µm Exclusion limit Pullulan Plate number TP per column Size mm Shipping solvent F6378010 SUGAR KS 801 Sulfo Na 6 1 000 17 000 8 0 x 300 H2O F6378020 SUGAR KS 802 Sulfo Na 6 10 000 17 000 8 0 x 300 H2O F6378025 SUGAR KS 803 Sulfo Na 6 50 000 17 000 8 0 x 300 H2O F6378035 SUGAR KS 804 Sulfo Na 7 400 000 17 000 8 0 x 300 H2O F6378050 SUGAR KS 805 Sulfo Na 17 5 000 000 9 000 8 0 x ...

Страница 3: ...n such a way that the arrow mark on the column will point to the direction of the flow Caution Do not let the air into the column during the connection 4 Heat the column to 40 50 C and start the pump Caution i Keep the column pressure below 5 MPa per column otherwise the column will be ruined ii The maximum working flow rate depends on the working temperature as follows Working temperature Maximum...

Страница 4: ...3 Cap both ends of the column place it back in the same case in which it was delivered from the manufacturer and store the case in a place where the temperature does not vary more than 5 C from the ambient temperature Caution i Do not remove the end fittings of the column otherwise its performance will deteriorate or the column may be rendered unserviceable ii Do not let the in column solvent free...

Страница 5: ...S 802 2 5 ethylene glycol aqueous solution 5µL KS 803 0 5 ethylene glycol aqueous solution 15 µL KS 804 0 8 glucose aqueous solution 5 µL KS 805 0 4 glucose aqueous solution 5 µL KS 806 0 8 glucose aqueous solution 5 µL 2 Mobile phase distilled water 3 Flow rate 1 0 mL min 4 Column temperature 50 C 5 Detector High sensitivity refractive index detector such as Shodex RI 6 Calculation formula NTP 5 ...

Страница 6: ... following cases 3 1 If the Shodex product is not used in accordance with the operating manual 3 2 If the Shodex product is remodelled by anyone other than person or firm designated by Showa Denko K K 3 3 If the Shodex product is disposed of 3 4 If the Shodex product is resold by the user without giving prior written notice to Showa Denko K K 3 5 If the performance of the Shodex product is not con...