Shivaki SRH-I076BE Скачать руководство пользователя страница 1

WALL MOUNTED 

SPLIT-TYPE

 

AIR CONDITIONERS

CONTENTS

1.

 

 

IMPORTANT NOTICE     

 ···································2 

2

OPERATION DETAILS

·······································

3

3

WIRING DIAGRAM                           

············· 

1

1

4

EXPLOSION VIEW

 AND PARTS LIST

·············

12

 

Models

SSH-I076BE/SRH-I076BE      

 

SSH-I096BE/SRH-I096BE

 

       

   SSH-I126BE/SRH-I126BE 

  

 

    

  

  

  

  
  

OB207t-1qxp  25/9/97 8:51 PM  Page 1

SHIVAKI

    

SERVICE MANUAL 

No.TE

150107 

Содержание SRH-I076BE

Страница 1: ... CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 OPERATION DETAILS 3 3 WIRING DIAGRAM 11 4 EXPLOSION VIEW AND PARTS LIST 12 Models SSH I076BE SRH I076BE SSH I096BE SRH I096BE SSH I126BE SRH I126BE SHIVAKI SERVICE MANUAL No TE150107 ...

Страница 2: ... information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or improvement without any prior notice The accurate specifications are presented on the nameplate label How to order spare parts To have your order filled promptly and correctly please furnish the following information 1 Model No ...

Страница 3: ...utton ECO button ON OFF button FAN SPEED button TEMP UP button TIMER button SLEEP button TEMP DOWN button To select the mode of operation In cooling mode press this button the temperature will increase 2 on the base of setting temperature In heating mode press this button the temperature will decrease 2 on the base of setting temperature To switch the conditioner on and off To select the fan speed...

Страница 4: ...hen being turned on or the power supply is resumed if the auto restart function activated power down after power on while if the auto restart function isn t activated the A C enters standby state Heat pump Mode Initial RT Initial ST Cooling RT 26 C 23 C Dry 26 C RT 20 C 7 C Heating RT 20 C 23 C Cooling only Mode Initial RT Initial ST Cooling RT 26 C 23 C Dry 26 C RT 20 C 7 C Ventilating RT 20 C Un...

Страница 5: ...he compressor run simultaneously except for defrosting 3 The control of indoor fan motor a Indoor fan motor can operate by automatic low middle and high airflow speed circularly b Indoor fan motor automatic airflow speed control it works as shown in Figure 2 Figure 2 Heat automatic airflow When the temperature change leads the fan speed variation the switch can only be made orderly and every grade...

Страница 6: ...etermined and adjusted Figure 3 Condition 2 When running time is more than or equal to 120 min compressor is running accumulatively the indoor temperature is less than 35 C for 2 min sustained Running into defrosting under condition 2 defrosting time set is 8 min Condition 3 after the compressor is operating for 20min continuously the indoor pipe temperature is less than 23 C cold air prevention w...

Страница 7: ...ting if any one below condition met a Defrosting time is over b When it runs in defrosting for three minutes the IPT indoor coil temperature rises 15 C or above from the bottom point 2 The quitting conditions for option 3 When OPT 20 C or defrosting for more than 10 min then quit from defrosting 3 Defrosting process shown in Figure 4 Figure 4 Defrosting process 7 Auxiliary electric heating functio...

Страница 8: ... to operate by pressing the emergency switch as follows To Press the emergency switch in three seconds the buzzer rings once and to release the machine runs into cooling mode if to holding on the buzzer rings twice then the machine runs into heating mode while when the machine is on to press the Emergency switch the buzzer rings once and then the machine shut down 2 The machine is running mandator...

Страница 9: ... 5 he compress the indoor will be sto r running ks the va mal vane an cordingly t Figure eed fan C C Conditioner Se the auto rest activated re on once thi er on If th n the comp tion the com essor s state ator cooling n compress T 5 C detect restores the ps if IPT 6 PT 48 C ou e e once the ed accordin the indoor f sor stop inc fan motor i pped forcibly at a low spe ne immedi gle While he vane turn...

Страница 10: ...ure is out of the range 50 C T 110 C then sensor failure is determined Once RT IPT sensor failures appear the compressor stops and indoor and outdoor fan motors shut off Remote controller doesn t response to any signal except for shutdown During failure the machine can run in fan mode After the failure is settled the PCB restores to standby status b Failure protection of Indoor PG fan motor If the...

Страница 11: ...Air Conditioner Service Manual 11 WIRING DIAGRAM MODEL SSH I076BE SRH I076BE SSH I096BE SRH I096BE SSH I126BE SRH I126BE INDOOR UNIT OUTDOOR UNIT ...

Страница 12: ...Air Conditioner Service Manual 12 EXPLOSION VIEW Mode SSH I076BE SSH I096BE SSH I126BE INDOOR UNIT 15 6 14 11 13 12 8 10 9 7 1 5 4 3 2 19 18 17 16 23 24 21 20 22 26 25 ...

Страница 13: ...ower Supply Cord 1 15 1070251837AE Vane 1 16 1070110011 Drainage Hose 1 17 1070040004 Cable Clamp 1 18 210900789 Main PCB 1 19 1070320113 Electrical Box 1 20 1170020011 Vane Motor 1 21 1073010501 Sensor Holder 1 22 1170030047 Indoor Motor 1 23 1070320111 Indoor Motor Cover 1 24 1170240001 Transformer 1 25 1170230001 Indoor Sensor Assembly 1 26 1080320818AB In And Out Pipe Fixer 1 27 1090050298BU R...

Страница 14: ...ower Supply Cord 1 15 1070251837AE Vane 1 16 1070110011 Drainage Hose 1 17 1070040004 Cable Clamp 1 18 210900789 Main PCB 1 19 1070320113 Electrical Box 1 20 1170020011 Vane Motor 1 21 1073010501 Sensor Holder 1 22 1170030047 Indoor Motor 1 23 1070320111 Indoor Motor Cover 1 24 1170240001 Transformer 1 25 1170230001 Indoor Sensor Assembly 1 26 1080320818AB In And Out Pipe Fixer 1 27 1090050298BU R...

Страница 15: ...ower Supply Cord 1 15 1070321034AE Vane 1 16 1070110011 Drainage Hose 1 17 1070040004 Cable Clamp 1 18 210900585 Main PCB 1 19 1070320113 Electrical Box 1 20 1170020011 Vane Motor 1 21 1073010501 Sensor Holder 1 22 1170030047 Indoor Motor 1 23 1070320111 Indoor Motor Cover 1 24 1170240001 Transformer 1 25 1170230001 Indoor Sensor Assembly 1 26 1080320818AB In And Out Pipe Fixer 1 27 1090050298BU R...

Страница 16: ...Air Conditioner Service Manual 16 EXPLOSION VIEW MODEL SRH I076BE SRH I096BE SRH I126BE OUTDOOR UNIT 10 11 12 8 9 7 6 5 17 13 14 16 15 19 18 20 21 23 22 24 4 3 2 25 26 27 1 ...

Страница 17: ... Right Plate 1 15 1120120025 Two way Valve 1 16 1081990013 Valve Supporter 1 17 1120130039 Three way Valve 1 18 1073521301 Electrical Box Cover 1 19 1070040001 Cable Clamp φ6 1 20 1070040002 Cable Clamp φ7 1 21 1170500131 Terminal 1 22 1170100031 Fan Motor Capacitor 1 23 1170100014 Compressor Capacitor 1 24 1080010002 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 211206830 Capillary As...

Страница 18: ...Right Plate 1 15 1120120025 Two way Valve 1 16 1081990013 Valve Supporter 1 17 1120130039 Three way Valve 1 18 1073521301 Electrical Box Cover 1 19 1070040001 Cable Clamp φ6 1 20 1070040002 Cable Clamp φ7 1 21 1170500131 Terminal 1 22 1170100031 Fan Motor Capacitor 1 23 1170100014 Compressor Capacitor 1 24 1080010002 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 211206477 Capillary Ass...

Страница 19: ... Right Plate 1 15 1120120021 Two way Valve 1 16 1080050003 Valve Supporter 1 17 1121990040 Three way Valve 1 18 1070350971 Electrical Box Cover 1 19 1070040001 Cable Clamp φ6 1 20 1070040002 Cable Clamp φ7 1 21 1170500131 Terminal 1 22 1170100010 Fan Motor Capacitor 1 23 1170100004 Compressor Capacitor 1 24 1080010006 Capacitor Strip 1 25 1081990010 Electrical Parts Box 1 26 1120351190 Capillary A...