3.4.2 Condensation Drainage Pipe
During normal operation, it will generate condensation water. Connect the water
pipe at drainage outlet to remove the condensation water is necessary.
1) Drainage pipe inner diameter should not less than the diameter of
drainage outlet.
2) Drainage pipe should be long enough to approach the drainage channel,
and be the hose. Be careful not to press or bend the pipe for smooth water
flow (Use the rigid pipe if there
’
s need to press or bend the hose).
3) As condensation water drainage is in terms of gravity, make sure the
drainage outlet is above the pipe. Otherwise the water can
’
t be drained out
and will flow back to the machine.
3.5 Cyclone Dust Collector
Picture 3-4: Installation Dia. of Cyclone Dust Collector
Cyclone Dust Collector Installation Steps:
1) Connect 1 and 5 with a heat-resistant duct and fixed both the ends with
stainless steel tube.
2) Connect 2 and 3 with a heat-resistant duct and fixed both the ends with
stainless steel tube.
3) Connect 4 and 6 with a heat-resistant duct and fixed both the ends with
stainless steel tube.